Инструкции По Обслуживанию для Bunn G9 HD

Скачать
Страница из 16
Page 8
SERVICE
 
This  section  provides  procedures  for  testing 
and  replacing  various  major  components  used  in 
this grinder should service become necessary. Refer 
to Troubleshooting for assistance in determining the 
cause of any problem.
WARNING - Inspection, testing, and repair of electri-
cal equipment should be performed only by qualified 
service personnel. The grinder should be disconnected 
from the power supply when servicing, except when 
electrical  tests  are  required  and  the  test  procedure 
specifically states to plug-in the grinder.
Component Access
WARNING - Disconnect the grinder from the power 
supply before the removal of any panel or the replace-
ment of any component. 
 
All components are accessible by the removal of 
the upper and lower front inspection panels, top lid, 
rear panel, and hopper.
The upper front inspection panel is attached with 
two 6-32 screws.
The lower front inspection panel is attached with 
two 6-32 screws.
The  top  lid  is  attached  with  four  6-32  screws. 
These screws need only to be loosened for lid removal. 
P602
PERSONAL INJURY
HAZARD.
KEEP FINGERS AND
FOREIGN OBJECTS
OUT OF HOPPER 
OR CHUTE OPENING.
CAUTION
P603
P1306
P1307
P1308
10171 042707
The rear panel is attached with eight 8-32 screws.
The hopper/extension assembly is attached with 
six 8-32 screws.
Contents
Motor -------------------------------------------------- 9
Off/On/Start Switch ----------------------------------11
Urn/Caraffe Switch ----------------------------------11
Relay --------------------------------------------------12
Timer --------------------------------------------------13