Справочник Пользователя для Marantz PD4201
PDxx01
RS-232C Control Specification Page: 10 / 49
Document Version [1.0]
Company Restricted
5-7.
CONTRAST Gain Data
Function
The external control equipment changes the CONTRAST gain data of the plasma monitor.
Transmission Data
The external control equipment changes the CONTRAST gain data of the plasma monitor.
Transmission Data
DFH 80H 60H 7FH 03H DATA00 DATA01 DATA02 CKS
DATA00: USER PICTURE Gain Flag
01H
DATA01: CONTRAST Gain Flag
07H
DATA02: CONTRAST Gain
CCH: -52
:
FFH:
-01
00H:
0
01H:
+01
:
14H:
+20
ACK
7FH 60H 80H 7FH 02H DATA00 DATA01 CKS
DATA00: USER PICTURE Gain Flag
01H
DATA01: CONTRAST Gain Flag
07H
5-8.
BRIGHT Gain Data
Function
The external control equipment changes the BRIGHT gain data of the plasma monitor.
Transmission Data
The external control equipment changes the BRIGHT gain data of the plasma monitor.
Transmission Data
DFH 80H 60H 7FH 03H DATA00 DATA01 DATA02 CKS
DATA00: USER PICTURE Gain Flag
01H
DATA01: BRIGHT Gain Flag
08H
DATA02: BRIGHT Gain
E0H: -32
:
FFH:
-01
00H:
0
01H:
+01
:
20H:
+32
ACK
7FH 60H 80H 7FH 02H DATA00 DATA01 CKS
DATA00: USER PICTURE Gain Flag
01H
DATA01: BRIGHT Gain Flag
08H