Справочник Пользователя для Marantz PD4201

Скачать
Страница из 49
  PDxx01  
       RS-232C Control Specification                                                      Page: 15 / 49 
Document Version [1.0]
 
Company Restricted 
 
 
 5-17. 
NR MODE Set 
Function 
The external control equipment sets the NR (Noise Reduction) mode of the plasma monitor. 
 
Transmission Data 
  DFH  80H  60H  C0H  01H  DATA00  CKS 
 
DATA00:   01H: NR OFF 
 02H: 
NR-1 
 03H: 
NR-2 
 04H: 
NR-3 
 
ACK 
  7FH  60H  80H  C0H  01H  DATA00  CKS 
 
DATA00:   01H: NR OFF 
  
02H: 
NR-1 
  
03H: 
NR-2 
  
04H: 
NR-3 
 
 5-18. 
BASS Gain Data 
Function 
The external control equipment changes the BASS gain data of the plasma monitor. 
 
Transmission Data 
    DFH    80H    60H    7FH    03H    DATA00    DATA01    DATA02    CKS 
 
DATA00: USER PICTURE Gain Flag     
 
05H 
 
DATA01: BASS Gain Flag   
 
 
03H 
 
DATA02: BASS Gain   
 
 
F3H: -13 
  
 
 
 
 
 
 
FFH : -01 
  
 
00H: 
  
 
01H: 
+01 
  
 
 
 
 
 
0DH : +13 
ACK 
  7FH  60H  80H  7FH  02H  DATA00  DATA01  CKS 
 
DATA00: USER PICTURE Gain Flag     
 
05H 
 
DATA01: BASS Gain Flag   
 
 
03H