Справочник Пользователя для Marantz PD4201

Скачать
Страница из 49
  PDxx01  
       RS-232C Control Specification                                                      Page: 21 / 49 
Document Version [1.0]
 
Company Restricted 
 
 
 5-31. 
GRAY LEVEL Set   
Function 
The external control equipment sets the GRAY LEVEL of the plasma monitor. 
 
Transmission Data 
  DFH  80H  60H  C6H  01H  DATA00  CKS 
 
DATA00: GRAY LEVEL 
 
00H: 0 
  
 
  
0FH: 
15 
ACK 
  7FH  60H  80H  C6H  01H  DATA00  CKS 
 
DATA00: GRAY LEVEL 
 
00H: 0 
  
 
  
0FH: 
15 
 
 5-32. 
CINEMA MODE Set   
Function 
The external control equipment switches on or off the CINEMA MODE of the plasma monitor. 
 
Transmission Data 
  DFH  80H  60H  C1H  01H  DATA00  CKS 
 
DATA00: CINEMA MODE Set   
 
 
 
01H: ON 
 
 
 
 
 
 
 
 
 
 
02H: OFF 
ACK 
  7FH  60H  80H  C1H  01H  DATA00  CKS 
 
DATA00: CINEMA MODE Set   
 
 
 
01H: ON 
 
 
 
 
 
 
 
 
 
 
02H: OFF 
 
 5-33. 
LONG LIFE Set (PDP SAVER Set) 
Function 
The external control equipment sets the PLE, ORBITER, and INVERSE (inverse of image brightness) or WHITE of the plasma 
monitor. 
 
Transmission Data 
    DFH    80H    60H    6BH    03H    DATA00    DATA01    DATA02    CKS 
 
DATA00: PLE 
 
01H: 100% (AUTO) 
 
 
02H: 75% (LOCK1) 
 
 
03H: 50% (LOCK2) 
 
 
04H: 25% (LOCK3) 
 
DATA01: INVERSE/WHITE 
 
01H: INVERSE 
  
02H: 
OFF 
  
03H: 
WHITE 
 
DATA02: ORBITER (PICTURE SHIFT)  
01H: AUTO1 
  
 
02H: 
OFF 
  
 
03H: 
AUTO2 
ACK 
The plasma monitor returns the following ACK when setting the PLE, ORBITER, and INVERSE (inverse of image brightness) or 
WHITE: 
  3FH  60H  80H  6BH  00H  CKS