Инструкции По Установке для Bosch ltc-0335-28

Скачать
Страница из 188
126 en | Encoders / Decoders page
Bosch Video Management System
Configuration Client | V3 | 2010.07
Configuration Manual
Bosch Sicherheitssysteme GmbH
18.16
Network > JPEG posting page
This function allows you to save individual JPEG images on an FTP server at specific intervals. 
Then, retrieve these images at a later date to reconstruct alarm events, if required.
Image size
Select the resolution for the JPEG images.
File name
Select how file names are created for the individual images that are transmitted.
Overwrite
The same file name is always used. An existing file is overwritten by the current file.
Increment
A number from 000 to 255 is added to the file name and automatically incremented by 1. 
When the number reaches 255, the number starts again from 000.
Date/time suffix
The date and time are automatically added to the file name. Ensure that the date and 
time of the device are always set correctly. For example, the file 
snap011008_114530.jpg was stored on October 1, 2008 at 11.45 and 30 seconds.
Posting interval (s; 0 = Off)
Enter the interval in seconds at which the images is sent to an FTP server. Enter zero for no 
images to be sent.
FTP server IP address
Type the IP address of the FTP server on which to save the JPEG images.
FTP server login
Type your login name for the FTP server.
FTP server password
Type the password for the FTP server.
Path on FTP server
Type the exact path where to save the images on the FTP server.
Post JPEG from camera
Select the check box to activate the camera input for the JPEG image. The numbering follows 
the labeling of the video inputs on the device.
18.17
Service > License page
This page allows you to enable additional functions or software modules.
Installation code
Displays the installation code.
Activation key
Type the activation key. The activation key cannot be deactivated and is not transferable to 
other units.
Installed licenses
Displays the installed licenses after their activation.