Дополнительное Руководство для Hoshizaki rh1-aac
13
B. Control Module
The control module for -AAC models is located on the face of the refrigeration circuit,
behind the front panel. To open the front panel, swing the bottom of the panel up and allow
the panel hinges to catch securely on the side panel frames in the locked position; the
control module can then be accessed.
behind the front panel. To open the front panel, swing the bottom of the panel up and allow
the panel hinges to catch securely on the side panel frames in the locked position; the
control module can then be accessed.
1. Settings and Adjustments.
a) Current Temperature Display
• The cabinet temperature is displayed on the control module. The cabinet temperature is
displayed in °F only.
• The cabinet temperature is updated every seconds.
• When the fan, compressor and defrost are initiated, the corresponding indicator lights
• When the fan, compressor and defrost are initiated, the corresponding indicator lights
will switch on.
b) Temperature Setpoint
The temperature setpoint is the temperature at which the compressor comes on. For
refrigerators, the temperature differential for the compressor to turn off is 5°F below the
setpoint. For freezers, the temperature differential for the compressor to turn off is 6°F
below the setpoint, If necessary, adjust the setpoint temperature as follows:
refrigerators, the temperature differential for the compressor to turn off is 5°F below the
setpoint. For freezers, the temperature differential for the compressor to turn off is 6°F
below the setpoint, If necessary, adjust the setpoint temperature as follows:
1) Press "SET." The display reads:
SP1
) Press "SET." The display reads:
Current Setpoint
3) Use the up/down arrows to change the setpoint. For refrigerators, the cabinet
temperature is adjustable between 37°F and 55°F. The factory default is 39°F. For
freezers, the cabinet temperature is adjustable between -10°F and 8°F. The factory
default is -1°F for the FH1-AAC(-HD) and 0°F for the FH-AAC(-HD).
freezers, the cabinet temperature is adjustable between -10°F and 8°F. The factory
default is -1°F for the FH1-AAC(-HD) and 0°F for the FH-AAC(-HD).
4) Press "SET" to save. If no button is pressed in 15 seconds, the display will return to
normal, and the setpoint will remain unchanged.
Control Module
Door
Front Panel