E. Alarm Signals and Countermeasures
If an error occurs, the alarm code and cabinet temperature are displayed in -second 
intervals and an alarm sounds. See the table below for a description of the problem.
Alarm Signals
Alarm Code
Alarm 
Sound Problem
Reset Options
E1
3 beeps 
every ten 
seconds
High Temperature Alarm
 
[Freezers with Board Revision Level 10 or 
Below and All Refrigerators]
 
Cabinet temperature has exceeded set 
temperature by 10°F (5.6°C) for more than  
hours.
 
[Freezers with Board Revision Level 11 
and Above] 
Cabinet temperature has exceeded set 
temperature by 5°F (13.9°C) for more than 
4 hours. 
(When the unit is turned on, the first display 
reads "r_##", where "##" indicates the board 
revision level.)
Press "RESET." If temperature has returned 
to setpoint range, alarm will stop and "E1" will 
clear. 
If temperature is not back in range, "RESET" 
will silence the alarm for 5 minutes. "E1" will 
continue to flash.
E
4 beeps 
every ten 
seconds
Low Temperature Alarm
Cabinet temperature has remained below 
setpoint by 8°F (4.4°C) for more than 1 hour.
Press "RESET." If temperature has returned 
to setpoint range, alarm will stop and "E" will 
clear. 
 
If temperature is not back in range, "RESET" 
will silence the alarm for 5 minutes. "E" will 
continue to flash.
E3 
[Freezer Only]  
(may alternate 
with "dEF" 
instead of 
temperature)
5 beeps 
every ten 
seconds
Defrost Alarm 
Defrost has taken longer than 1 hour. Control 
board has terminated defrost.
Press "RESET." Alarm will stop and "E3" will 
clear. 
 
If 4 consecutive defrosts take more than 1 
hour, a qualified service technician must be 
called. 
 
For the service tech to reset this alarm, press 
"ALARM RESET" on the control board itself.
E4
6 beeps 
every ten 
seconds
High Pressure Alarm
Compressor discharge pressure is outside 
normal operating range. Pressure switch has 
been triggered 3 or more times in 1 hour.
If switch trips 5 times in 1 hour, compressor 
will be stopped and will not restart.
Press "RESET." If pressure switch resets 
automatically, alarm will stop and "E4" will 
clear when pressure switch closes. After 5 
pressure trips, the alarm can be silenced for 1 
hour by pressing the "RESET". 
 
For the service tech to reset this alarm, press 
"ALARM RESET" on the control board itself.
E6
8 beeps 
every ten 
seconds
High Voltage Alarm 
Line voltage has been too high for at least 
10 seconds. To protect the compressor , the 
compressor has shut down.
Alarm automatically resets when acceptable 
voltage is detected. 
Press "RESET" to silence alarm for 5 minutes. 
E7
9 beeps 
every ten 
seconds
Low Voltage Alarm
 
Line voltage has been too low for at least 
10 seconds. To protect the compressor , the 
compressor has shut down.
Alarm automatically resets when acceptable 
voltage is detected. 
Press "RESET" to silence alarm for 5 minutes.