Техническое Руководство для GE dpvh890ej

Скачать
Страница из 4
Dryer Exhausting Information – Metal Duct Only
For complete information, see installation instructions packed with your dryer.
Ducting Materials: For best performance, this dryer should be vented with 4” diameter 
all rigid metal exhaust duct. If rigid metal duct cannot be used, then UL-listed flexible
metal (semi-rigid) ducting can be used (Kit WX08X10077). In special installations, it may
be necessary to connect the dryer to the house vent using a flexible metal (foil-type) duct.
A UL-listed flexible metal (foil-type) duct may be used ONLY in installations where rigid
metal or flexible metal (semi-rigid) ducting cannot be used AND where a 4” diameter can
be maintained throughout the entire length of the transition duct. Please see installation 
instruction packed with your dryer for complete instructions when using flexible metal (foil
type) ducting. 
Exhaust Length Calculation:
1.  Determine the number of 90° turns needed for your installation. If you exhaust to the  
  side or bottom of dryer, add one turn.
2.  The maximum length of 4’ rigid (aluminum or galvanized) duct which can be tolerated is  
  shown in the table.
 A turn of 45° or less may be ignored. Two 45° turns within the duct length should be  
  treated as a 90° elbow. 
  A turn over 45° should be treated as a 90° elbow.
Dryers 
must be exhausted to the outside.
Caution: For personal safety do not terminate exhaust into a chimney, under any enclosed
house floor (crawl space), or into an attic, since the accumulated lint could create a fire 
hazard or moisture could cause damage. Never terminate the exhaust into a common duct
or plenum with a kitchen exhaust, since the combination of lint and grease could create a
fire hazard.
Exhaust ducts should be terminated in a dampered wall cap to prevent back drafts, bird
nesting, etc. The wall cap must also be located at least 12" above the ground or any other
obstruction with the opening pointed Down.
For more information on venting kits and accessories, please call 1-800-GE-CARES.
Listed by 
Underwriters 
Laboratories
Specification Revised 5/09
270198
DPVH890EJ 
GE Profile
 7.5 Cu. Ft. Colossal Capacity Electric Dryer With Steam
 
Best performance
Domestic  
dryer models
Maximum length of 4"
dia. 
rigid metal duct
Number
of
90°
turns
Exhaust hood type
A
4" 
opening
B
2-1/2" 
opening
7.5 and 7.3 cu. ft.  
capacity electric  
and gas dryers
4
150 ft.
140 ft.
130 ft.
120 ft.
110 ft.
127 ft.
117 ft.
107 ft.
97 ft.
87 ft.
A
4
B
2-1/2
A