Руководство Пользователя для Intellinet 519021
Modularized 24+2G Switch
87
4-3-6-3. 802.1x PerPort Configuration
In this page, set the authorization status to activate 802.1x function by
port setting.
In this page, set the authorization status to activate 802.1x function by
port setting.
1. Select <Edit>.
2. Status: Press <Space> key to choose Fu / Fa / Au / No authorization
2. Status: Press <Space> key to choose Fu / Fa / Au / No authorization
status.
3. Press Ctrl+A go back action menu line.
4. Select <Save> to save all configure value.
4. Select <Save> to save all configure value.
Fu: Force the specific port to be unauthorized.
Fa: Force the specific port to be authorized.
Au: The state of the specific port that was determined by the outcome of
the authentication.
No: The specified port does not support IEEE 802.1x function.
Fa: Force the specific port to be authorized.
Au: The state of the specific port that was determined by the outcome of
the authentication.
No: The specified port does not support IEEE 802.1x function.
Modularized 24+2G Switch
88
4-3-6-4. 802.1x Misc Configuration
1. Press
<Edit>.
2. Quiet Period: Used to define period of time during which it will not
attempt to acquire a supplicant (Default time is 60 seconds).
3. Tx Period: Used to determine when an EAPOL PDU is to be
transmitted (Default value is 30 seconds).
4. Supplicant Timeout: Used to determine timeout conditions in the
exchange between the supplicant and authentication server (Default
value is 30 seconds).
value is 30 seconds).
5. Server Timeout: Used to determine timeout conditions in the exchange
between the authenticator and authentication server (Default value is 30
seconds).
seconds).
6. ReAuthMax: Used to determine the number of re-authentication
attempts that are permitted before the specific port becomes
unauthorized (Default value is 2 times).
unauthorized (Default value is 2 times).
7. Reauth Period: Used to determine a nonzero number of seconds
between periodic re-authentication of the supplications (Default value
is 3600 seconds).
is 3600 seconds).
8. Press Ctrl+A go back action menu line.
9. Press <Save> to save configures value.