Справочник Пользователя для Printronix SL5000r
Running Media Profile
77
Advanced Gap Sensing
This figure shows a Media Profile printout of a smart label where Gap/Mark
Sensor is set to Advanced Gap in the CALIBRATE CTRL menu.
Sensor is set to Advanced Gap in the CALIBRATE CTRL menu.
In this example, the gap threshold value the printer selected (represented by
the Gap/Mark dotted line) is too close to the amplitude of the antenna pulse.
If there is an increase in noise or the opacity of the liner or ribbon, the printer
may falsely use the antenna or noise as the gap (top-of-form).
the Gap/Mark dotted line) is too close to the amplitude of the antenna pulse.
If there is an increase in noise or the opacity of the liner or ribbon, the printer
may falsely use the antenna or noise as the gap (top-of-form).
255
191
127
063
000
Paper Out(075)
Adv. Gap(030)
Detected Amplitude
of the Antenna
Detected Amplitude
of the Gap
Media Sensor
Position
FEED
Indicates Type of Gap/Mark
Sensing Selected