Справочник Пользователя для Printronix P7000

Скачать
Страница из 338
154
Chapter
4
LinePrinter Plus Emulation (With PCL-II)
Upr. Case Select
Controls how the printer handles lowercase characters it receives from the 
host computer. When enabled, all characters will be printed in uppercase.
Disable (default). Prints lowercase characters received from the host 
computer as lowercase, and prints uppercase characters received from 
the computer as uppercase.
Enable. Prints lowercase characters received from the host computer as 
their corresponding uppercase equivalents; uppercase characters 
received from the computer print as uppercase.
Slew Relative
“Slewing” is rapid vertical paper movement. This parameter determines the 
number of lines slewed (either 1-15 lines or 1-16 lines) when an EVFU Slew 
Relative command is received. The options include:
1-15 Lines (default)
1-16 Lines 
Serial Matrix Emulation
Printer 
Protocol
Control Code 
06
Define CR 
Code
Auto LF
Overstrike
Define LF 
Code
Printer
Select
Alt. Set
80-9F
Character
Set
ESC d 
command
8.0 LPI*
10.3 LPI
6.0 LPI
CR = CR*
CR = CR + LF
Enable*
Disable
Enable*
Disable
LF = LF*
LF = CR + LF
Disable*
Enable
Control Code*
Printable
(see page 157) Even dot plot*
Double high
* = Factory Default
Serial
Matrix