RFID MAX RETRY
Check System
Error Handling = Overstrike in 
the RFID (or RFID 
CONTROL) menu, and the 
Label Retry count has been 
exhausted.
Press PAUSE to clear the 
message.
See “Troubleshooting” on 
page 90
.
RFID TAG ERR:
Read-Only Tag
A write was attempted on a 
read-only tag.
Press PAUSE to clear the 
message.
Change media to writable 
tags or remove the write 
command from the 
application.
RFID TAG FAILED
Check Media
Error Handling = Stop in the 
RFID (or RFID CONTROL) 
menu, and the RFID encoder 
could not read the RFID tag.
Press PAUSE to clear the 
message.
See “Troubleshooting” on 
page 90
.
RFID UNLOCK CMD:
Not Supported!
An unlock command was 
executed on a tag which does 
not support locking.
Press PAUSE to clear the 
message.
Remove the unlock 
command from the 
application.
RFID ACS FIELD:
Not Supported!
The ACS field was accessed 
on a tag which does not 
support the ACS field.
Press PAUSE to clear the 
message.
Remove references to the 
ACS field from the 
application.
RFID KIL FIELD:
Not Supported!
The KIL field was accessed 
on a tag which does not 
support the KIL field.
Press PAUSE to clear the 
message.
Remove references to the 
KIL field from the 
application.
RFID PC FIELD:
Not Supported!
The PC field was accessed 
on a tag or RFID encoder 
which does not support the 
PC field.
Press PAUSE to clear the 
message.
Remove references to the 
PC field from the application.
Table 5. Control Panel Error Messages