Техническое Руководство для Quantum DLT VS80
![Quantum](https://files.manualsbrain.com/attachments/ca899287dff61d1f33a1c7bab7817a3b487b137c/common/fit/150/50/f93012c635c78a826a2112e2b27bef1217df419ecadb31ba968d3a8a7575/brand_logo.jpeg)
Chapter 7: Electromagnetic Compatibility
7-4
May 2004
001597-01 Rev. A09
7.3
Immunities
The DLT VS80 tape drive meets or exceeds the electromagnetic immunity limits required in the
following specifications:
following specifications:
•
EMC Directive (89/336/EEC)
•
EN55024: 1998 Information Technology Equipment - Immunity
•
CISPR 24: 1997 Information Technology Equipment - Immunity.
7.3.1 ESD Immunity
lists the EN 61000-4-2:1995 ESD immunity limits for operator access areas.
N
OTE
: The product meets Quantum reliability levels (air discharge to 10 kV, with
15 kV desired).
7.3.2 Radiated Immunity
lists the EN 61000-4-3:1995 radiated immunity limits.
Table 7-5.
ESD Immunity Limits
Parameter
Performance Criteria
Contact discharge + 4 kV
Air discharge + 8 kV
No operator intervention
(soft recoverable errors allowed)
(soft recoverable errors allowed)
Table 7-6.
Radiated Immunity 80 to 1000 MHz
Parameter
Performance Criteria
80 – 1000 MHz, 1 kHz (80% AM)
900 MHz, 200 Hz, 3 V/m
No errors allowed