LTO Autoloader Barcode Reader
 
 
Optical Specification  
The optical specifications for the bar code labels are listed below.  
!  Use the white calibration standard to calibrate the print contrast of the Mcbeth PCMII. Be 
sure the filter select switch is on position A for all calibration and measurements.  
!  The reflectivity of the white background (RW) is the reflectivity measured in the center of 
narrow spaces using the Mcbeth PCMII print contrast meter. The RW must be between 
70% and 85%. At this measurement, isolated print defects and edge roughness are 
avoided.  
!  A spot is defined as an area anywhere within the white background in which the 
reflectivity is less than 65%. Spots may not be greater than 0.004 inches (0.102 mm) 
enclosed diameter. There may be no more than five spots in the bar code area per label. 
Spots may not be any closer to each other than 0.01 inches (0.254 mm).  
!  The reflectivity of the black areas (RB) may be measured anywhere within any black 
area on the bar code. The print contrast signal (PCS) is defined as (RW-RB)/RW and is 
measured using the Mcbeth PCMII print contrast meter. PCS must be a minimum of 
0.85. Using the PCS measurement will avoid isolated print defects and edge roughness.  
!  A void is an area within a black area where the PCS is less than 0.85. No voids may be 
greater than 0.004 inches (0.102 mm) enclosed diameter. There may be no more than 
five voids in the bar code area per label. Voids may not be any closer to each other than 
0.01 inches (0.254 mm). 
 
Note: For additional optical requirements and measurement techniques, refer to the AIM Uniform 
Symbol USS-39 specification. 
 
Label Dimensions 
The following figure shows the bar code label dimensions.  
Note: Dimensions are given in inches with millimeters in parentheses. 
 
 
Character orientation:  horizontal (recommended) 
Barcode orientation: 
    bottom 
 
 
 
 
 
 
 
 
Recommended supplier: EDP/Colorflex