Справочник Пользователя для Champion pp-3
C O N T R O L P A N E L S
Timer Operation
The change water timer (t) will retain its current count when the washer is stopped or when
power has been disconnected from the controller.
power has been disconnected from the controller.
The soap delay timer (t2) allows for a delay before soap is dispensed into the wash tank.
This will allow the soap to be added to a wash tank when it is full of water and the
circulation pumps are running.
This will allow the soap to be added to a wash tank when it is full of water and the
circulation pumps are running.
The soap dispensing timer (
τ3) determines the time for soap dispensing. A time of 0.00 will
bypass the soap dispensing process.
Keypad Operation
Used to decrement or modify a parameter value, or to show the software version when in configuration/calibration mode.
Used to increment or modify a parameter value, or to show the heater sheath temperature
Used to scroll the display to the next parameter and to store a modified parameter value
Used to cycle the circulation pumps and to restart the washer after a change water cycle has been completed
Used to decrement or modify a parameter value, or to show the software version when in configuration/calibration mode.
Used to bypass the change water status, this resets the change water timer and advances the controller
to the fil state.
to the fil state.
Note
: Buttons must be pressed in the order shown, and held for roughly 15 seconds.
+
+
Used to enable / disable the display lamp test.
NOTE:
Buttons must be pressed in the order shown.
Used to access the supervisor mode.
NOTE
: Buttons must be pressed in the order shown, and held for roughly 3 seconds.
+
19