C O N T R O L   P A N E L S  
 
Timer Operation 
The change water timer (t) will retain its current count when the washer is stopped or when 
power has been disconnected from the controller. 
The soap delay timer (t2) allows for a delay before soap is dispensed into the wash tank. 
This will allow the soap to be added to a wash tank when it is full of water and the 
circulation pumps are running. 
The soap dispensing timer (
τ3) determines the time for soap dispensing. A time of 0.00 will 
bypass the soap dispensing process. 
Keypad Operation 
 
 
 
 
 
 
 
 
 
 
Used to decrement or modify a parameter value, or to show the software version when in configuration/calibration mode. 
 
Used to increment or modify a parameter value, or to show the heater sheath temperature 
 
Used to scroll the display to the next parameter and to store a modified parameter value 
 
Used to cycle the circulation pumps and to restart the washer after a change water cycle has been completed 
 
Used to decrement or modify a parameter value, or to show the software version when in configuration/calibration mode. 
 
Used to bypass the change water status, this resets the change water timer and advances the controller 
to the fil state. 
Note
: Buttons must be pressed in the order shown, and held for roughly 15 seconds. 
Used to enable / disable the display lamp test. 
NOTE:
Buttons must be pressed in the order shown. 
Used to access the supervisor mode.  
NOTE
: Buttons must be pressed in the order shown, and held for roughly 3 seconds. 
19