Листовка для Infocus Ceiling Mount Extension Arm: 6-9" SP-EXTARM-01

Модели
SP-EXTARM-01
Скачать
Страница из 2
ISSUED: 11-08-04     SHEET NO: 154-9007-1
Visit the InFocus Web Site at www.infocus.com
1 of 2
Installation and Assembly - InFocus
®
 Adjustable Extension Column
IMPORTANT!
  Read entire instruction sheet before
beginning installation and assembly.
Attach threaded end of adjuster tube (B) to threaded fitting in
ceiling plate. Align slot in end of adjuster tube (B) with one of the
holes in the side of threaded fitting. Insert and tighten one M5 x
.8 x 10 mm phillips screw (E) to lock adjuster tube (B) to
threaded fitting.
Optional: For security use M5 socket pin screw (provided with
projector mount) instead of M5 phillips screw (E). Tighten
using security allen wrench (provided with projector mount).
Description
Qty.
SP-EXTARM-01
SP-EXTARM-02
SP-EXTARM-03
SP-EXTARM-04
A
extension pipe
1
154-1025
154-1032
154-1034
154-1003
B
adjuster tube
1
154-1028
154-1030
154-1030
2MD-55VS11D
E
M5 x .8 x 10 mm phillps screw
1
520-9250
520-9250
520-9250
520-9250
F
M10 x 60 mm carriage bolt
1
580-1022
580-1022
580-1022
580-1022
M10 center lock nut
1
530-9402
530-9402
530-9402
530-9402
Models:
SP-EXTARM-01
SP-EXTARM-02
SP-EXTARM-03
SP-EXTARM-04
R
This product is intended for use with UL
Listed products and must be installed by a
qualified professional installer.
Maximum Load Capacity : 900 lb (408 kg)
ceiling plate
(sold separately)
B
• Installer must verify that mounting surface will safely
support four times the combined weight of all attached
equipment and hardware.
WARNING
• Adjuster tube (B) must be fully threaded (six or seven
full turns) onto threaded fitting in ceiling plate and then
locked with screw (E).
WARNING
E
PART'S LIST