28
C3461M  (7/09)
Switch Settings
WARNING: If you are using Pelco D-type or Pelco P-type control, your system may not operate if 
the baud rate and address switches are not set correctly. The switches are set at the factory using 
the defaults for Pelco D-type control (2400 baud and address 1).
Table D. Switch Settings for SW2
Special Systems
Switch  Number
1
2
3
4
5
6
7
8
9
10
AD-32 Preset System
ON
CM9502 Setting
ON
Vicon
Not currently available; SW2-3 is reserved for future use.
Serial Port Settings
Switch  Number
1
2
3
4
5
6
7
8
9
10
RS422
OFF
OFF
RS485, 4-Wire
OFF
ON
RS485, 2-Wire
ON
ON
Pelco D or Pelco P Protocol Baud Rate
Switch  Number
1
2
3
4
5
6
7
8
9
10
2400 Baud
(Default for D-type Control)
  
OFF
OFF
OFF
4800 Baud
(Default for P-type Control)
ON
OFF
OFF
9600 Baud
OFF
ON
OFF
Video Cable Type
Switch  Number
1
2
3
4
5
6
7
8
9
10
Coaxial Cable
OFF
Dome Termination
Switch  Number
1
2
3
4
5
6
7
8
9
10
Terminated
ON
Not Terminated
OFF