Location Requirements
You will need
A location that allows for proper exhaust installation. A gas 
dryer must be exhausted to the outdoors. See “Venting 
Requirements.”
A grounded electrical outlet located within 2 ft (61 cm) of 
either side of the dryer. See “Electrical Requirements.”
A sturdy floor to support the dryer and a total weight (dryer 
and load) of 200 lbs (90.7 kg). The combined weight of a 
companion appliance should also be considered.
A level floor with a maximum slope of 1" (2.5 cm) under entire 
dryer. (If slope is greater than 1" [2.5 cm], install Extended 
Dryer Feet kit, Part No. 279810.) Clothes may not tumble 
properly and models with automatic sensor cycles may not 
operate correctly if dryer is not level.
Do not operate your dryer at temperatures below 45ºF (7ºC). At 
lower temperatures, the dryer might not shut off at the end of an 
automatic cycle. Drying times can be extended.
The dryer must not be installed or stored in an area where it will 
be exposed to water and/or weather.
Check code requirements. Some codes limit, or do not permit, 
installation of the dryer in garages, closets, mobile homes, or 
sleeping quarters. Contact your local building inspector.
NOTE: No other fuel-burning appliance can be installed in the 
same closet as a dryer.
Installation Clearances
The location must be large enough to allow the dryer door to 
open fully. 
Dryer Dimensions
*Most installations require a minimum 5" (12.7 cm) clearance 
behind the dryer for the exhaust vent with elbow. See “Venting 
Requirements.”
Installation spacing for recessed area or closet installation
The following spacing dimensions are recommended for this 
dryer. This dryer has been tested for spacing of 0" (0 cm) 
clearance on the sides and rear. Recommended spacing should 
be considered for the following reasons:
Additional spacing should be considered for ease of 
installation and servicing.
Additional clearances might be required for wall, door and 
floor moldings.
Additional spacing should be considered on all sides of the 
dryer to reduce noise transfer.
For closet installation, with a door, minimum ventilation 
openings in the top and bottom of the door are required. 
Louvered doors with equivalent ventilation openings are 
acceptable.
Companion appliance spacing should also be considered.  
*Required spacing
WARNING
Explosion Hazard
Keep flammable materials and vapors, such as
gasoline, away from dryer.
Place dryer at least 18 inches (46 cm) above the floor
for a garage installation.
Failure to do so can result in death, explosion, or fire.
A. Small Opening Side-Swing Door
B. Large Opening Side-Swing Door
C. Wide Opening Side-Swing Door
D. Wide Opening Hamper Door
A. Recessed area
B. Side view - closet or confined area
C. Closet door with vents
 
   
 
   
   
 
   
43
³⁄₈
"
(110 cm)
*26"
(66 cm)
29"
(73.66 cm)
A
15¼"
(38.74 cm) 43
³⁄₈
"
(110 cm)
*27¾"
(70.5cm)
29"
(73.66 cm)
B
22 ¾"
(57.8 cm)
43
³⁄₈
"
(110 cm)
13 ¾"
(34.9 cm)
*27 ¾"
(70.5 cm)
29"
(73.66 cm)
D
43
³⁄₈
"
(110 cm)
*27 ¾"
(70.5 cm)
29"
(73.66 cm)
C
22 ¾"
(57.8 cm)
 
A
B
C
    18"*
(45.7 cm)
  1"
(2.5 cm)
       29"
(73.66 cm)
        1"
   (2.5 cm)
        1"*
    (2.5 cm)
14" max.*
(35.6
 
cm)
   27¾"
(70.5 cm)
   5"*
 (12.7 cm)
  48 in.  
(310 cm  )
2
*
2
  24 in.
(155 cm  )
*
2
       3"*
(7.6 cm)
       3"*
(7.6 cm)