Руководство Пользователя для Insinger ensign 40-2

Скачать
Страница из 38
Initial Start-Up Adjustments
Tank Overfill Adjustment
1. Locate tank overfill timer in the control panel.
See the control panel layout drawing located in
Section 6, Electrical Schematic and Replace-
ment Parts.
2. The overfill timer starts timing when the upper
level float is actuated. Adjust the overfill timer
potentiometer to turn the tank fill solenoid off
when the water level is 1/4” below the lip of the
overflow tube.
3. The timer has a built in dwell timing delay of 5
seconds (nominal to dampen float bounce
caused by tank water motion.
Conveyor Jam Adjustment
1. Remove the mechanism guard to gain access
to the conveyor drive.
2. Locate the compression spring (refer to Draw-
ing #1397-1, Drive Mechanism Assembly).
3. The factory set compression dimension is a
nominal 3 13/16”. Installations washing heavier
ware may need to adjust this for more compres-
sion to keep the machine from shutting down
prematurely.
4. Should the drive mechanism switch be acti-
vated by a conveyor jam, the Check Conveyor
Light on the control panel will illuminate and the
machine will shut down.
5. To restart the machine, clear the jam and press
the green Start Button.
Final Rinse Pressure Adjustment
1. The final rinse pressure must be adjusted to
20PSI. This is done by adjusting the pressure
regulator.
PART 2 INSTALLATION INSTRUCTIONS