3 Operation
Figure 3.1 Front Panel Controls and Indicators
3.4  Front Panel Controls 
and Indicators
A. Cooling Vents
Front-to-rear forced airflow through foam dust filter.
LCD Control Screen and Controls
B. LCD Control Screen
Integrated LCD with white backlight, controls ampli-
fier setup and operation. 
       The LCD Control Screen and its controls let the user 
adjust the amplifier's attenuation and muting, con-
figure the amp, set up and view error monitoring 
(such as temperature and load supervision), and 
recall DSP presets. The presets allow the user to 
quickly reconfigure the amp for various applica-
tions.
C. Level Controls (Encoders)
Speed-sensitive, 0.5 dB steps, range 0 to –100 dB. 
These two knobs affect the Channel-1 and
Channel-2 output levels. They also select Menu 
items and adjust parameter values that are displayed 
on the LCD control screen. 
D. Menu/Exit Button
“Menu” enters the main menu. “Exit” leaves the 
menu.
E. Prev Button
Selects the previous item in the menu.
F. Next Button
 Selects the next item in the menu.
Thermal and Fault Indicators
G. Clip Indicator
Red LED, one per channel, illuminates when the 
channel’s output signal reaches the onset of audible 
clipping. The Clip Indicator also will illuminate dur-
ing Thermal Level Control (TLC) limiting.
H. Thermal Indicator
Red LED, one per channel, illuminates when the 
channel has shut down due to thermal stress or 
overload.
I.
Fault Indicator
Red LED, one per channel, flashes when the ampli-
fier output channel has stopped operating. Usually 
this means that the amplifier must be serviced.
Signal Indicators
Three green LEDS per channel indicate the ampli-
fier’s input and output signal levels. From top to bot-
tom the LEDs are:
J. –10 dB: amplifier output is 10 dB below clipping.
K. –20 dB: amplifier output is 20 dB below clipping. 
L. Signal: input signal is above –40 dBu.
A
B
C
D
E
F
J
I
H
G
O
P
Q
M
L
K
N
M. Ready Indicator
Green LED, one per channel, illuminates when the 
channel is initialized and ready to produce audio out-
put. Indicator is off when the channel is set to standby 
mode via System Architect or the IQ system.
N. Power Indicator
Blue LED indicates amplifier has been turned on and 
AC power is available. The LED will flash when the AC 
line voltage is 15% above or below the nominal rated 
range.
O. Bridge Mode Indicator
Yellow LED illuminates when the amplifier is set to 
Bridge-Mono mode.
P. Data Indicator
Yellow LED indicates HiQnet or IQ data activity. Data 
indicator flashes only when the amplifier is polled for 
data, or is polled to see whether it is online.
Q. Power Switch
Push-on/push-off switch glows green when AC power 
is present at the power cord and the amplifier circuit 
breaker is in the “on” position.