Техническая Спецификация для Hussmann e2s

Скачать
Страница из 7
4 ft
6 ft
8 ft
12 ft
General
(A) Case Length (without ends or partitions)
48 
1
/
8
(1222)
72 
1
/
(1832)
96 
1
/
4
(2445)
144 
3
/
8
(3667)
Maximum O/S dimension back to front 
(with bumper)
46 
1
/
2
(1181)
46 
1
/
2
(1181)
46 
1
/
2
(1181)
46 
1
/
2
(1181)
Back of case to front of front panel
34 
1
/
(876)
34 
1
/
(876)
34 
1
/
(876)
34 
1
/
(876)
Back of case to O/S edge of front skid rail
29 
3
/
(746)
29 
3
/
(746)
29 
3
/
(746)
29 
3
/
(746)
Width of skid rail
1
/
(114)
1
/
(114)
1
/
(114)
1
/
(114)
RH end of case to outside edge of external support
3
/
8
(34)
3
/
8
(34)
3
/
8
(34)
3
/
8
(34)
Distance between edges of 
external support and center support
NA
28 
1
/
(724)
40 
1
/
(1029)
40 
1
/
(1029)
Distance between edges of center supports
NA
NA
NA
44 (1118)
Distance between edges of external supports
37  (940)
NA
NA
NA
Stub-up area between front skid rail and front panel
3
/
(146)
3
/
(146)
3
/
(146)
3
/
(146)
Electrical Service                         (Electrical Field Wiring connection point)
(B) Length of electrical raceway
18 
3
/
8  
(467)
18 
3
/
8  
(467)
37 (940)
37 (940)
(C) RH End of case to center of farthest knockout
36 
5
/
8  
(930)
60 
3
/
4  
(1543)
84 
3
/
(2153)
132 
3
/
(3372) 
Back of case to center of end knockout
29 
5
/
(752)
29 
5
/
(752)
29 
5
/
(752)
29 
5
/
(752)
(D) RH End of case to RH end of raceway
27 
5
/
8  
(702)
51 
5
/
8  
(1311)
57 
1
/
4  
(1454)
105 
1
/
8  
(2670)
(E) LH End of case to LH end of raceway
1
/
8  
(54)
1
/
8  
(54)
2 (51)
1
/
4  
(57)
Waste Outlet
(F) RH End of case to the center of waste outlet
24 
1
/
(616)
24 
1
/
(616)
24 
1
/
(622)
72 
1
/
(1834)
LH End of case to the center of waste outlet
23 
7
/
(606)
47 
7
/
(1216)
71 
3
/
(1822)
72 
1
/
(1832)
Back O/S of case to center of waste outlet
27 
5
/
(702)
27 
5
/
(702)
27 
5
/
(702)
27 
5
/
(702)
Water Seal
Edge of water seal to center of waste outlet
4  (102)
4  (102)
4  (102)
4  (102)
Outside diameter of the drip pipe
1
/
(38)
1
/
(38)
1
/
(38)
1
/
(38)
NOTE: Water seal outlet must clear front skid rail;
water seal rotation in forward direction only due to low base.
Refrigeration Outlet
Back of case to center of refrigeration outlet
30 
3
/
(781)
30 
3
/
(781)
30 
3
/
(781)
30 
3
/
(781)
RH end of case to center of refrigeration outlet
3
/
(213)
3
/
(213)
3
/
(213)
3
/
(213)
E2S
Meat, Delicatessen 
Precut & Packaged 
Produce
41 In. High
2 of 7
E2S  Data Sheet
HUSSMANN CORPORATION, Bridgeton, MO  63044-2483  U.S.A.
Engineering
Plan Views
Dimensions shown as inches and (mm).
09-2005
34
 
1
/
2
(876)
8
 
3
/
8 
 
(213)
Electrical Service
29
 
5
/
8
(752)
Waste Outlet
Front
C
L
A
C
D
B
F
E
27
 
5
/
8
(702)
30
 
3
/
4
(781)
46
 
1
/
2
(1181)
Water Seal