Техническая Спецификация для Hussmann e2s
4 ft
6 ft
8 ft
12 ft
General
(A) Case Length (without ends or partitions)
(A) Case Length (without ends or partitions)
48
1
/
8
(1222)
72
1
/
8
(1832)
96
1
/
4
(2445)
144
3
/
8
(3667)
Maximum O/S dimension back to front
(with bumper)
46
1
/
2
(1181)
46
1
/
2
(1181)
46
1
/
2
(1181)
46
1
/
2
(1181)
Back of case to front of front panel
34
1
/
2
(876)
34
1
/
2
(876)
34
1
/
2
(876)
34
1
/
2
(876)
Back of case to O/S edge of front skid rail
29
3
/
8
(746)
29
3
/
8
(746)
29
3
/
8
(746)
29
3
/
8
(746)
Width of skid rail
4
1
/
2
(114)
4
1
/
2
(114)
4
1
/
2
(114)
4
1
/
2
(114)
RH end of case to outside edge of external support
1
3
/
8
(34)
1
3
/
8
(34)
1
3
/
8
(34)
1
3
/
8
(34)
Distance between edges of
external support and center support
NA
28
1
/
2
(724)
40
1
/
2
(1029)
40
1
/
2
(1029)
Distance between edges of center supports
NA
NA
NA
44 (1118)
Distance between edges of external supports
37 (940)
NA
NA
NA
Stub-up area between front skid rail and front panel
5
3
/
4
(146)
5
3
/
4
(146)
5
3
/
4
(146)
5
3
/
4
(146)
Electrical Service (Electrical Field Wiring connection point)
(B) Length of electrical raceway
(B) Length of electrical raceway
18
3
/
8
(467)
18
3
/
8
(467)
37 (940)
37 (940)
(C) RH End of case to center of farthest knockout
36
5
/
8
(930)
60
3
/
4
(1543)
84
3
/
4
(2153)
132
3
/
4
(3372)
Back of case to center of end knockout
29
5
/
8
(752)
29
5
/
8
(752)
29
5
/
8
(752)
29
5
/
8
(752)
(D) RH End of case to RH end of raceway
27
5
/
8
(702)
51
5
/
8
(1311)
57
1
/
4
(1454)
105
1
/
8
(2670)
(E) LH End of case to LH end of raceway
2
1
/
8
(54)
2
1
/
8
(54)
2 (51)
2
1
/
4
(57)
Waste Outlet
(F) RH End of case to the center of waste outlet
(F) RH End of case to the center of waste outlet
24
1
/
4
(616)
24
1
/
4
(616)
24
1
/
2
(622)
72
1
/
4
(1834)
LH End of case to the center of waste outlet
23
7
/
8
(606)
47
7
/
8
(1216)
71
3
/
4
(1822)
72
1
/
8
(1832)
Back O/S of case to center of waste outlet
27
5
/
8
(702)
27
5
/
8
(702)
27
5
/
8
(702)
27
5
/
8
(702)
Water Seal
Edge of water seal to center of waste outlet
4 (102)
4 (102)
4 (102)
4 (102)
Outside diameter of the drip pipe
1
1
/
2
(38)
1
1
/
2
(38)
1
1
/
2
(38)
1
1
/
2
(38)
NOTE: Water seal outlet must clear front skid rail;
water seal rotation in forward direction only due to low base.
water seal rotation in forward direction only due to low base.
Refrigeration Outlet
Back of case to center of refrigeration outlet
30
3
/
4
(781)
30
3
/
4
(781)
30
3
/
4
(781)
30
3
/
4
(781)
RH end of case to center of refrigeration outlet
8
3
/
8
(213)
8
3
/
8
(213)
8
3
/
8
(213)
8
3
/
8
(213)
E2S
Meat, Delicatessen
Precut & Packaged
Produce
41 In. High
2 of 7
E2S Data Sheet
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
Engineering
Plan Views
Dimensions shown as inches and (mm).
09-2005
34
1
/
2
(876)
8
3
/
8
(213)
Electrical Service
29
5
/
8
(752)
Waste Outlet
Front
C
L
A
C
D
B
F
E
27
5
/
8
(702)
30
3
/
4
(781)
46
1
/
2
(1181)
Water Seal