HE225A,B AND HE265A,B BY-PASS FLOW-THROUGH HUMIDIFIERS WITH AGION
5
69-1423EF—05
Vacation
The humidifier water supply and your humidity control can be turned off. Turn on 
humidifier water supply and reset your humidity control when you return.
CHECKING YOUR HUMIDIFIER OPERATION
After winter startup or servicing, check the humidifier operation:
1. Turn on the humidifier power and water supply.
2. Turn H8908B Control to highest setting or H1008A Control to test position; set 
thermostat to 10°F (6°C) above room temperature.
NOTE: The H1008A Automatic Humidity Control stays in test mode for thirty minutes. 
Then it automatically resets to the maximum frost factor setting. If system 
checkout is not completed in thirty minutes, test mode can be extended by 
turning dial setting back and then returning it to test mode.
3. Observe that water is flowing out of the drain hose.
NOTE: The furnace blower must be on to activate the humidifier.
4. Reset thermostat and H8908A Control to comfortable setting or H1008A 
Automatic Control to desired frost factor setting for automatic operation.
TROUBLESHOOTING YOUR HUMIDIFIER
Problem
What to Look for
What to Do
Low humidity
Furnace blower not 
operating.
•Reset circuit breaker or replace fuse.
•Check that the furnace power is on.
•Check all external wiring connections.
•Check humidity control setting.
•Call a heating contractor.
Rapid air changes. Drafts 
(cold air is dry and is an 
added load to humidifier).
•Keep doors and windows closed.
•Close fireplace damper if not using.
•Minimize exhaust fan running time.
•Seal around doors and windows. 
High humidity
Condensation on walls.
•Turn off humidity control and water until 
condensation is completely evaporated.
Heavy condensation on 
windows.
•Turn humidity control low enough to 
eliminate bath and cooking 
condensation moisture. If moisture 
persists, more ventilation is needed.