WARNING LABEL IDENTIFICATION
FAILURE TO OBSERVE THE FOLLOWING WARNINGS COULD RESULT IN INJURY.
Always wear eye protection
when operating or perform-
ing maintenance on this tool.
WARNING
WARNING
Always wear hearing
protection when operating
this tool.
Always turn off the air sup-
ply and disconnect the air
supply hose before install-
ing, removing or adjusting
any accessory on this tool,
or before performing any
maintenance on this tool.
WARNING
Air powered tools can vibrate
in use. Vibration, repetitive
motions or uncomfortable po-
sitions may be harmful to your
hands and arms. Stop using
any tool if discomfort, tingling
feeling or pain occurs. Seek
medical advice before resum-
ing use.
WARNING
Do not carry the tool by the
hose.
WARNING
WARNING
Do not use damaged, frayed
or deteriorated air hoses
and fittings.
WARNING
Keep body stance balanced
and firm. Do not overreach
when operating this tool.
WARNING
Operate at 90 psig (6.2 bar/
620 kPa) Maximum air pres-
sure.
90 psig
(6.2bar/620kPa)
ADJUSTMENTS
SETTING THE POWER REGULATOR
Impact wrenches are not torque wrenches.
Connections requiring specific torque must be checked
with a torque meter after fitting with an impact
wrench.
Model 216 Impact Wrench incorporates a power regulator
mechanism that allows the operator to regulate the power
output in both directions. To adjust the power, proceed as
follows:
There are no detents or markings on the Regulator.
Experience will dictate the amount of rotation needed
to power down the Impact Wrench.
For full power in both directions, 
rotate the Air
Regulator Assembly (23), at the bottom of the handle to
the full out position.
For reduced power in both directions, select the power
required by rotating the Air Regulator Assembly (23), at
the bottom of the handle, until the appropriate power
setting is selected.
PLACING TOOL IN SERVICE
LUBRICATION
Ingersoll--Rand No. 50
Always use of an air line lubricator with these tools.
We recommend the following Filter--Lubricator--Regulator
Unit:
For International-- No. C28--C4--FKG0
For USA-- No. C28--04--FKG0--28
After each eight hours of operation, 
unless the air line
lubricator is used, detach the air hose an inject about
1--1/2 cc of oil into the Inlet Bushing (14).
After each forty--eight hours of operation, or as
experience indicates, remove the Oil Chamber Plug (4)
and fill the impact mechanism oil chamber with the
recommended oil.
MAIN LINES 3 TIMES
AIR TOOL INLET SIZE
TO
AIR
SYSTEM
TO
AIR
TOOL
LUBRICATOR
REGULATOR
FILTER
BRANCH LINE 2 TIMES
AIR TOOL INLET SIZE
DRAIN REGULARLY
COMPRESSOR
(Dwg. TPD905--1)
SPECIFICATIONS
Model
Type of
Handle
Drive
Impacts
per min.
Recommended
Torque Range
H
Sound Level
dB (A)
Vibrations
Level
in.
ft--lbs (Nm)
Pressure
Power
m/s
2
216
palm
3/8” sq.
1750
15--130
(20--176)
92.9
105.9
1.8
H
Tested in accordance with PNEUROP PN8NTC1.2
♦ Tested to ISO8662--7