5.3 Get-Function 
Listing 
 
The PC can interrogate the LCD Monitor for specific information. The Get-Function packet format 
consists of 5 bytes which is similar to the Set-Function packet structure. Note that the “Value” byte is 
always = 00. 
 
Get-Function description:   
Length:  
Total Byte of Message excluding “CR” 
TV ID 
Identification for each of TV 
Command Type 
Identify command type,   
“g” (0x67h) : Get Command 
Command:  
Function command code: One byte ASCII code   
Value[1~3]:  
Three bytes ASCII that defines the value   
CR 
0x0D 
 
Get-Function format   
Send: (Command Type=”g”) 
Name  
Length 
ID 
Command Type
Command
Value1 
Value2 
Value3  
CR  
Byte 
Count  
1 Byte   
2 Byte 
1 Byte 
1 Byte   
1 Byte 
1 Byte 
1 Byte   
1 Byte   
Bytes 
order 
1 2~3 
6  7  8  9 
Reply: (Command Type=”r” or “-”)
 
If the Command is valid, Command Type =”r” 
Name  
Length 
ID 
Command Type
Command
Value1 
Value2 
Value3  
CR  
Byte 
Count  
1 Byte   
2 Byte 
1 Byte 
1 Byte   
1 Byte 
1 Byte 
1 Byte   
1 Byte   
Bytes 
order 
1 2~3 
6  7  8  9 
If the Command is Not valid, Command Type=”-“ 
Name  
Length ID Command 
Type
CR 
Byte 
Count  
1 Byte   
2 Byte 
1 Byte 
1 Byte 
Bytes 
order 
1 2~3 
 
Example1: Get Brightness from TV-05 and this command is valid.   
The Brightness value is 67. 
Send (Hex Format)   
Name  
Length 
ID 
Command Type
Command
Value1 
Value2 
Value3  
CR  
Hex  
0x38 0x30 
0x35 
0x67 0x62 0x30 0x30 0x30 0x0D 
Reply(Hex Format) 
Name  
Length 
ID 
Command Type
Command
Value1 
Value2 
Value3  
CR  
Hex  
0x38 0x30 
0x35 
0x72 0x62 0x30 0x36 0x37 0x0D 
 
Example2: Get Brightness from TV-05 , but the Brightness command ID is error 
and it is NOT in the command table. 
Send (Hex Format)   
Name  
Length 
ID 
Command Type
Command
Value1 
Value2 
Value3  
CR  
Hex  
0x38 0x30 
0x35 
0x67 0XD3 0x30 0x30 0x30 0x0D 
Reply (Hex Format) 
Name  
Length ID Command 
Type
CR 
Hex  
0x34 0x30 
0x35 