The unit may be installed directly adjacent to the existing base cabinets.  IMPORTANT - The side trim MUST be 
3
/
8
(.95 cm) above the adjacent base cabinet countertop.  The unit CANNOT be installed directly adjacent to sidewalls, tall
appliances, or other side vertical surfaces above 36” (91.4 cm) high.  There must be a minimum of 6” (15.2 cm) side
clearance for the VGWT/VGGT models and 9” (22.9 cm) side clearance for the VGQT models to such combustible
surfaces above 36” (91.4 cm) counter height.  Within the side clearance to combustible vertical surfaces above 36”
(91.4 cm), the maximum wall cabinet depth must be 13” (33.0 cm) and wall cabinets within this side clearance must be
18” (45.7 cm) above the 36” (91.4 cm) high countertop.  The wall cabinet above the appliance must be a minimum of
42” (106.7 cm) above the appliance cooking surface for a full width of the unit.
13” MAX.
(33.0 cm)
42” MIN.
(106.7 cm)
A
18” MIN.
(45.7 cm)
36”
(91.4 cm)
71/2”
(19.1 cm)
24”
(60.9cm)
A
A
V
VG
GW
WT
T
6” (15.2 cm)
V
VG
GG
GT
T
6” (15.2 cm)
V
VG
GQ
QT
T
9” (22.9 cm)