Руководство Пользователя для Vitek vtc-750wdr

Скачать
Страница из 20
VTC-C750WDR 
 
 
11
 
 
 
 
 
 
 
 
 
 
 
7.6 ZONE ADJ menu 
 
Adjusts the size and the location of the metering zone for the dynamic range control. 
Dynamic range control is very sensitive to the size and the location of the zone. 
The default window size is SAFE AREA. 
 
To enter ZONE ADJ menu, press 
  button at <ZONE ADJ . . .> of WDR CUSTOM menu. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
In ZONE ADJ menu, 'NEXT:MENU-' stands for 'press 
  button short for next menu'   
and 'RETURN:MENU---' means 'press 
  button longer than 2 sec for return or exit'. 
,
,
,
  buttons are used for move, enlarge or reduce the zone. 
 
White zone boundary moves the zone to locate it at the optimal position. 
Green zone boundary enlarges the zone. 
Red zone boundary reduces the zone. 
 
 
7.7 BLC ZONE SELECT menu 
 
To enter BLC ZONE SELECT menu, press 
  button at <BLC . . .            > of EXPOSURE menu. 
 
 
 
 
 
 
 
 
Metering of the backlit compensation control is weighted to the selected window from CTR SPOT(1/9 of   
entire screen), UPPER 1/3, MIDDLE 1/3 and LOWER 1/3. 
 
 
WDR 
CUSTOM 
Descriptions 
WINDOW 
Metering of the dynamic control is weighted to the selected window from SAFE AREA, 
ZONE ADJUST, CENTER 1/3 AND LOWER 2/3. 
RANGE 
Adjusts the strength of the dynamic range control. 
BIAS 
Adjusts the base level of the dynamic range control.