4. Loosen ④  Back focus Adjustment Lock Screw one~two turns on the camera with industrial “+” driver   
5. Rotate ①  Back Focus Adjustment until the optimum focus is achieved. 
6. Tighten ④  Back focus Adjustment Lock Screw
 
again. 
7.  Trim the focus precisely at lens if necessary. 
 
Setting for lenses with a variable focal distance (zoom) 
If the focus changes as the focal distance changes, please proceed as follows. 
1.  Point the camera at an object with sufficient contrast at a distance of approximately 2 meters. 
2.  Open the iris on the lens 
3.  Set the maximum focal distance (Tele) at the lens 
4.  Set the optimum focus with the focus ring 
5.  Set the smallest focal distance (wide angle) 
6. Loosen ④  Back focus Adjustment Lock Screw one~two turns on the camera with the industrial “+” driver 
7. Adjust ①  Back Focus Adjustment until the optimum focus is achieved. Steps 3,4,5 and 7 may be needed 
to repeat several times to obtain the best results 
8. Tighten ④  Back focus Adjustment Lock Screw again 
 
5.3. Installation 
 
The camera has a 1/4” thread insert on its top and bottom side for mounting the camera to a tripod or the wall 
or ceiling with a corresponding mount. 
 
5.4 Commissioning 
 
  Connect the power to the camera firstly 
  Plug the power adaptor to the mains supply secondly 
 
 
Power indicator LED will be lit 
  The camera is ready for operation 
 
5.5. Power Supply Connections 
 
Camera can work with either 12VDC or 24VAC, dual voltage power. It does NOT require the polarity-matched 
connection for 12VDC supply. Primary and secondary grounds are completely isolated to avoid the possible 
ground-loop problems. Its excellently wide operating voltage range of 10.5V-30V for DC and 12-28.8V for AC 
gives an extra flexibility at the installation. 
 
 
 
 
 
 
 
6. Start up 
 
When the camera is powered properly, it starts up with initializing the internal parameters and the filter switch 
mechanism. The filter switch unit repeats IN and OUT two times at each power up and just after RESTORE 
FACTORY SETTINGS.