Справочник Пользователя для Intel I7-975
Datasheet
75
Thermal Specifications
6.1.2
Thermal Metrology
The minimum and maximum TTV case temperatures (T
CASE
) are specified in
,
and
and are measured at the geometric top center of the thermal test vehicle
integrated heat spreader (IHS).
CASE
temperature measurements should be made. For detailed guidelines on temperature
measurement methodology and attaching the thermocouple, refer to the appropriate
processor Thermal and Mechanical Design Guidelines (see
measurement methodology and attaching the thermocouple, refer to the appropriate
processor Thermal and Mechanical Design Guidelines (see
Notes:
1.
Figure is not to scale and is for reference only.
2.
B1: Max = 45.07 mm, Min = 44.93 mm.
3.
B2: Max = 42.57 mm, Min = 42.43 mm.
4.
C1: Max = 39.1 mm, Min = 38.9 mm.
5.
C2: Max = 36.6 mm, Min = 36.4 mm.
6.
C3: Max = 2.3 mm, Min = 2.2 mm
7.
C4: Max = 2.3 mm, Min = 2.2 mm.
8.
Refer to the appropriate Thermal and Mechanical Design Guide (see
) for instructions on
thermocouple installation on the processor TTV package.
Figure 6-2. Thermal Test Vehicle (TTV) Case Temperature (T
CASE