93 
E-SW-LDSPLUSRG-G 
LDS Plus Reference Guide 
Com2Xon – COM2 Software Flow Control 
Function 
The Com2Xon parameter enables or disables the use of software flow control (XON/XOFF) for 
communications port number 2 (COM2). 
Options 
Valid options:  
Disable, Enable 
Default setting: 
Disable 
Access Level 
Parameter may only be modified by a user with an access level of 2 or 3. 
Com2HwFlowCtrl – COM2 Hardware Flow Control 
Function 
The Com2HwFlowCtrl parameter specifies the hardware flow control setting for communications 
port number 2 (COM2). 
Options 
Valid options:  
Off, RTS/CTS, DTR/CTS 
Default setting: 
Off 
Access Level 
Parameter may only be modified by a user with an access level of 2 or 3. 
Com2TimeOut – COM2 Time Out 
Function 
The Com2TimeOut parameter enables or disables the time out feature for communications port 
number 2 (COM2). When enabled (On), a gap of more than 50ms between characters received on 
COM2 terminates the message.  
LDS Plus detects the end of an RS-232 message using a timeout. However, for optimum 
reliability, it is advised to configure the device to append a single terminating character suffix. 
Supported terminating characters are NUL (0x00), LF (0x0A) and CR (0x0D). This terminating 
character will be interpreted as an end-of-message marker by LDS Plus. 
Options 
Valid options:  
Off, On 
Default setting: 
Off 
Access Level 
Parameter may only be modified by a user with an access level of 2 or 3.