Emulation Menu Option 
55 
E-SW-LDSPLUSRG-G 
LDS Plus Reference Guide 
FormScrollMode – Scroll Form Contents 
Function 
The FormScrollMode parameter determines whether form contents can be scrolled up or down 
using the arrow keys. 
Regardless of the value set for this parameter, the cursor appears only in the unprotected character 
positions of a form. If none of the lines on the display contain unprotected fields, the cursor 
appears after the last character on the display. It will not allow any data entry as there are no 
unprotected fields. Upon loading a form, the computer displays the line of the form that contains 
the first unprotected field and as many of the preceding lines as possible. 
When the parameter is set to Yes, use the [Arrow] keys to view all lines (whether these lines 
contain unprotected fields or not). 
When the parameter is set to No, certain lines of a form may not be available for viewing on the 
display. 
Options 
Valid options:  
Yes, No 
Default setting: 
No 
Access Level 
Parameter may only be modified by a user with an access level of 2 or 3. 
StoredFormCall – Recall Stored Form 
Function 
The StoredFormCall parameter determines whether a form can be recalled using the keyboard. 
When the parameter is set to Yes, stored forms can be accessed with the keyboard. The host can 
also recall a stored form. 
When the parameter is set to No, stored forms cannot be accessed with the keyboard. 
Options 
Valid options:  
Yes, No 
Default setting: 
Yes 
Access Level 
Parameter may only be modified by a user with an access level of 2 or 3.