Руководство Пользователя для LXE mx3

Скачать
Страница из 380
216 
5380SF 2D Imager 
Integrated Scanner Programming Guide 
 
E-SW-SCANNERPG-L 
Integrated Imager Identification Label 
The label specifying which scanning engine is installed in the LXE mobile device may be on the back 
of the mobile device, next to the laser emission warning label. See Chapter 1 – Introduction, section 
titled Identify Your Barcode Reader Type and/or your system administrator for assistance. 
Note:  The function to use the imager like a camera (or for OCR decoding) is not supported in this 
release. 
Pre-Configured Default Values 
The following values are set by LXE before the mobile device is shipped. The imager can be returned 
to LXE factory defaults by scanning the Factory Default Settings barcode.  
LXE Factory defaults are listed in the following table. 
 
 
Figure 4-1  Pre-configured Default Values – 5380SF 2D Imager 
Imager Parameter 
Device Default Value 
General 
Factory Default Settings ............................................... As built 
Good Read Delay....................................................... No Delay 
Reread Delay ............................................................... Medium 
LED Power Level ..............................................................High 
Aimer Delay........................................................ Off (no delay) 
Centering Window...............................................Centering Off 
Print Weight.............................................................................4 
Working Orientation..................................................... Upright 
Intercharacter Delay.................................................... No delay 
Interfunction Delay..................................................... No delay 
Intermessage Delay..................................................... No delay 
Symbologies 
Codabar .............................................................................. On 
Start/Stop Characters ........................................ Don’t Transmit 
Check Character........................................ No Check Character 
Concatenation .......................................................................On 
Message Length ..............................................Min: 4 / Max: 60 
Code 39 ............................................................................... On 
Start/Stop Characters ........................................ Don’t Transmit 
Check Character........................................ No Check Character 
Message Length ..............................................Min: 0 / Max: 48 
Append................................................................................. Off 
Code 32 Pharmaceutical ...................................................... Off 
Code 39 Full ASCII ............................................................. Off 
Code Page ...........................................................Not Supported 
Interleaved 2 of 5 ............................................................... On 
Check Digit.......................................................No Check Digit 
Message Length ..............................................Min: 4 / Max: 80 
Code 93 ............................................................................... On 
Message Length ..............................................Min: 0 / Max: 80 
Code Page ...........................................................Not Supported 
Straight 2 of 5 Industrial................................................... Off