16 
Symbol Barcodes 
Integrated Scanner Programming Guide 
 
E-SW-SCANNERPG-L 
Pre-Configured Default Values 
Note:  The SE955 scanner replaced the SE824 scanner on all MX7’s manufactured after July 2006. It also 
replaced the SE923 scanner on all MX3X and MX3-RFID devices manufactured after July 2006. 
Mobile Device 
SE824 SE923 
SE955 SE1223 SE1224 SE1524 SE2223 
MX3X and MX3Plus 
 x 
x     
MX3-RFID (laser) 
 x 
x     
MX5X 
 
 
 x x    x 
MX7 
x  
x     x   
MX8 
 
 
x     
Figure 2-2  Pre-configured Default Values – Symbol Scan Engines 
All MX3 Mobile Devices – SE923, SE955 
All MX3s -  Scanner Parameter 
Default Value for SE923 
Default Value for SE955 
Set Default Parameter  
All Defaults 
All Defaults 
Scanning Options 
 
 
Aim Duration 
0.0 sec 
0.0 sec 
Aiming Mode 
Not Supported 
Not Supported 
Beeper Volume 
Not Supported 
Not Supported 
Bi-directional Redundancy 
Disable Disable 
Laser On Time 
3.0 sec 
3.0 sec. 
Linear Code Type Security Levels 
1 1 
Parameter Scanning 
Enable Enable 
Power Mode 
Low Power 
Low Power 
Raster Expansion Rate 
Not Supported 
Not Supported 
Raster Height 
Not Supported 
Not Supported 
Scan Angle (Clipping) 
No Clipping 
Not Supported 
Scan Angle 
Normal Wide 
Scanning Mode 
Not Supported 
Not Supported 
Time Delay to Low Power 
Not Supported 
Not Supported 
Time-out Between Different Symbols 
Not Supported 
Not Supported 
Time-out Between Same Symbol 
1.0 sec 
1.0 sec. 
Transmit “No Read” Message 
Disable Disable 
Trigger Mode 
Level Level