Руководство Пользователя для LXE mx3
338
5300 2D Imager
Integrated Scanner Programming Guide
E-SW-SCANNERPG-L
Posi Code
Syntax Posi=p1,p2,p3
Example Posi=0,4,48,2
Example Posi=0,4,48,2
Pn
Default Valid
Description
1
0
1 enable 0 disable
Decode Posi Code barcode
2
4
4 – 48
Minimum length to decode
3
48
4 – 48
Maximum length to decode
4
2
0=none 1=A 2=B
Limited setting
Postnet
Postnet = US Postal Service Postnet Code
Syntax Postnet=p1,p2
Example Postnet=0,0
Example Postnet=0,0
Pn
Default Valid
Description
1
0
1 enable 0 disable
Decode Postnet barcode
2
0
1 enable 0 disable
Transmit check digit
Usps4cb
USPS height-modulated barcode designed for use in high speed, automated, mail sorting machines
that allow both Planet and Postnet barcode information to be combined into a single barcode to track
mailings, request address-quality service.
that allow both Planet and Postnet barcode information to be combined into a single barcode to track
mailings, request address-quality service.
Syntax Usps4cb=p1
Example Usps4cb=0
Example Usps4cb=0
Pn
Default Valid
Description
1
0
1 enable 0 disable
Decode Usps4cb Code barcode
Sample SCANCONFIG.INI File
The SCANCONFIG.INI file used for 5300 2D imager configuration is located in the System folder
on the mobile device and has the format shown below:
on the mobile device and has the format shown below:
Note:
Do not insert spaces in the settings entries. For example:
DecodeMode=1 Correct
DecodeMode = 1
Incorrect
Default values are shown.
[Decoder]
DecodeMode=1
LinearRange=3
LeaveLightsOn=0
AimTimer=0