Posi  Code 
Syntax Posi=p1,p2,p3 
Example Posi=0,4,48,2 
Pn 
Default Valid 
Description 
1 enable 0 disable 
Decode Posi Code barcode 
4 – 48 
Minimum length to decode 
48 
4 – 48 
Maximum length to decode 
0=none 1=A 2=B 
Limited setting 
 
Postnet 
Postnet  = US Postal Service Postnet Code 
Syntax Postnet=p1,p2 
Example Postnet=0,0 
Pn 
Default Valid 
Description 
1 enable 0 disable 
Decode Postnet barcode 
1 enable 0 disable 
Transmit check digit 
 
Usps4cb 
USPS height-modulated barcode designed for use in high speed, automated, mail sorting machines 
that allow both Planet and Postnet barcode information to be combined into a single barcode to track 
mailings, request address-quality service. 
Syntax Usps4cb=p1 
Example Usps4cb=0 
Pn 
Default Valid 
Description 
1 enable 0 disable 
Decode Usps4cb Code barcode 
 
Sample SCANCONFIG.INI File 
The SCANCONFIG.INI file used for 5300 2D imager configuration is located in the System folder 
on the mobile device and has the format shown below: 
Note: 
Do not insert spaces in the settings entries. For example: 
 DecodeMode=1 Correct 
 
DecodeMode = 1 
Incorrect 
Default values are shown. 
 
[Decoder] 
DecodeMode=1 
LinearRange=3 
LeaveLightsOn=0 