Using the Multicharger 
MX6 Reference Guide 
 
E-EQ-MX6RG-E 
Using the Multicharger 
Note:  For best results, battery packs should be at room temperature before recharging them; 
temperature has a marked effect on charging. The recommended temperature range is 
50° to 95° F (10 
° to 35 ° C). 
 
Figure C-1  MX6 Multicharger Components 
Battery Capacity Indicator LED - Analyze 
2 Analyze 
Button 
3 Charge/Analyze 
Slot 
4 Charging 
Slots 
AC Power Jack (not seen) 
Power Switch (not seen) 
7 Charge 
Status 
LEDs 
1.  Push the barrel connector into the power jack at the back of the multicharger.  
2.  Plug the three prong connector end of the AC power supply into an AC wall outlet. 
3.  Toggle the Power switch to On. 
4.  The green power LED illuminates and the charger performs a self-diagnostic test that 
lasts approximately 5 seconds.  
The multicharger is ready for use. 
Inserting/Removing a Battery Pack 
Do not "slam" or drop the battery into the slot. Failure to follow this instruction can result in 
damage to the battery or the multicharger. 
Place the end of the battery pack without the locking tab into the bottom of the charging slot and 
snap the battery into place with a hinging motion. The status LED for that slot illuminates orange 
when the battery has been properly inserted. 
Remove the battery pack by pushing the locking tab down and then pulling the battery out of the 
slot with a hinging motion.