SPECIFICATIONS 
 
Width: 23 1/8”  
Height: 30 ½” 
Depth: 22 ¼” 
Weight: 233 lbs. 
Flue size: 3” or 4” 
Hopper Capacity: Up to 50 lbs. 
(This can vary widely depending on pellet 
size, length, and diameter) 
EPA status: exempt 
Burn time: 1 lb. to 5.5 lbs. per hour 
BTU range: 8,200 to 50,000 
Approved installations: mobile home, 
alcove, conventional 
 
PREPARATION 
 
Factory packaging must be removed, and 
some minor assembly work is required 
prior to installation. Access to the rear of 
the stove is necessary. 
 
NOTE: Normally, your dealer will perform 
these functions. 
 
CLEARANCES 
 
The Breckwell P2700 Freestanding has 
been tested and listed for installation in 
residential, mobile home and alcove 
applications. 
FLOOR PROTECTION: Freestanding 
installations, minimum 24” wide by 29” 
deep. The stove must be placed on a 
continuous (grouted joints) 
noncombustible material such as ceramic 
tile, cement board, brick, 3/8” millboard or 
equivalent, or other approved or listed 
material suited for floor protection. NOTE: 
ceramic tile, or any tile, requires a 
continuous sheet beneath to prevent the 
possibility of embers falling through to the 
combustible floor if cracks or separation 
should occur in the finished surface, this 
would include floor protection for Built-in 
raised hearths. Check local codes for 
approved alternatives. 
Clearances are measured from the sides, 
back and face (door opening) or stove 
body (refer to fig. 3).  
DO NOT USE MAKESHIFT MATERIALS 
OR COMPROMISES IN THE 
INSTALLATION OF THIS UNIT. 
INSTALL VENT WITH CLEARANCES 
SPECIFIED BY THE VENT 
MANUFACTURER. 
 
 
 
 
 
 
 
 
INSTALLATION 
FIGURE 1 
FIGURE 2 
FLOOR PROTECTION 
(MINIMUM 24” W X 29” D) 
FIGURE 3