Mains Operation And Leakage Power
The mains power consumption as well as the leakage power is stated for driving the power amplifier at
different levels. All the values were measured at nominal load via the 100 V output with two channels
driven. The shown values differ only slightly when the appliance is operated at different nominal output
voltages or in the Direct Out mode.
mains operation at the 
100 V output
U
mains
[V]
I
mains 
[A]
P
mains [VA]
P
mains 
[W]
P
out 
[W]
P
[W]
BTU/hr
CPS2T
idling
230V
120V
0,57
1.1
131
80
80
273
normal operation (-10 dB)
230V
120V
3,66
7.0
842
655
101
554
1890
nominal conditions
230V
120V
9,86
18.9
2268
1900
1000
900
3070
Extension Kits For The CPS2T:
NRS 90208 balanced input (input transformer for a single channel)
NRS 90235 1 pair of rack-mount ears
12