2
    All electrical repairs must be carried out
by qualified electricians. Inadequate repairs
may result in a major source of danger for
the user of the air conditoiner.
  Do not damage any parts of the air
conditioner that carry refrigerant by
piercing or perforating the air conditioner's
tubes with sharp or pointed items, crushing
or twisting any tubes, or scraping the
coatings off the surfaces. If the refrigerant
spurts out and gets into eyes, it may result
in serious eye injuries.
  Do not obstruct or cover the ventilation
grille of the air conditioner. Do not put
fingers or any other things into the
inlet/outlet and swing louver.
   Do not allow children to play with the air
conditioner. In no case should children be
allowed to sit on the outdoor unit.
Specifications
The refrigerating circuit is leak-proof.
1. Applicable ambient temperature range:
The machine is adaptive in following
situation
2. If the supply cord is damaged, it must be
    replaced by the manufacturer or its service
    agent or a similar qualified person.
3. If the fuse on PC board is broken please
    change it with the type of  T3.15A /250VAC.
Cautions
Cooling
Heating
Indoor
outdoor
Rated Maximum Minimum
  27           32             18
  19           23             14
  35           43              -5
  24           26              --
  20           27              15
 14.5          --               --
   7             21            -15
   6             15              --
DB  C
WB  C
DB  C
WB  C
Indoor
outdoor DB  C
WB  C
DB  C
WB  C
2
2
19
Other Instructions
1.Configuration of power supply
Air conditioner must use special power supply system (above 20A), and qualified electrician makes
wiring and fixing according to wiring regulations specified in national standard.
In socket, exactly distinguish earth wire with neutral wire and it is wrong to connect them together.
A leakage breaker must be installed.
Parameters of power supply: H07RN-F 3G 2.0
mm
2
Connection method is Y-connection .If the power cord is damaged, it must be replaced by
professional people of manufacturer or its maintenance department or similar to avoid dangers.
2.Pipe cutting and expanding
Must remove burrs if cut pipes with pipe cutter.
Expand flare after insert the pipe expander.
Installation check and test run
Require customers to use air conditioner according to the operation manual.
The items checked during test run,please mark       in
No gas leakage on the pipe joint ?
How about the thermal insulation of the pipe joint:
Is the electrical wiring between indoor and outdoor unit connected to the terminal block firmly?
Is the wiring of indoor and outdoor unit secured firmly?
Is the drainage hose arranged correct?
Is the earthing wire connected firmly?
Is the power supply voltage conformed to the electrical regulation?
Any noise?
Is the display on the control board (LCD) correct?
Cooling normal?
Does the indoor temperature regulator work normally?
For the power supply
L   shall be connected to the live wire.
N   shall be connected to the neutral wire.
Shall be connected to the earth wire.
The  person  who  has  completed  this  installation  shall  be  requested  to  conduct  a test  operation  for  check:
Is  the  temperature  adjuster  working  normally?
Does  the  location  for  installation  conform  to  requirements?
Winding  up  with  Protective  Plastic  Tape
The  connection  pipes, drain  pipe, and  the  connection  wires
 shall  be  wound  up  with   PVC  tape.
Notes: The  connection  pipes  shall  also  be  wound  up  with  insulating
 material  to  preserve  the temperature.  The  airing  direction  shall  be
from  bottom  to  top.
Trial  Operation
Correct
Incorrect
Deflection
Crack occurs
Broken
Incomplete
Over outward
A
Pipe expander
Liquid pipe
Gas pipe
Diameter of pipe
Dimension A (mm)
1.0~1.2
1.4~2.2
6.35mm (1/4î)
12.7mm (1/2î)
Installation Procedures,Check and Test Run
4. The wiring method should be in line with
     the local wiring standard.
5. Use copper wire only. The connecting cable
    should be H05RN-F 4G 0.75mm  . The power
    cable should be H05RN-F 3G 2.5mm  .
    All the cables shall have got the European
    authentication certificate.
6. The waste battery shall be disposed properly.
7. The indoor unit installation height is at least
    2.5m.
8. The appliance must be installation that the
    plug should be easily accessible after
    installation.
9. The power plug should be self-provided and
     it should have got the Local authenti-
     cation certificate.