Note: Pull out safety switch on door during 
product calibration cycle.  If switch is not 
pulled out to ”on” position the pumps will 
not operate, and an error code will flash, 
“P1, P2, or P3” 
Product Calibration Instructions
Overview:  Machine H2O settings are calibrated at the factory and 
normally do not need adjustment. Concentrate calibration
should be performed at initial machine set-up, and each
time the product density (or viscosity) changes.
(If same product is used, I.e. just changing out an empty box 
of the same product, channel does not need recalibration)
Should it become necessary to re-calibrate H2O settings,
see page 25
Step 1
Press & hold Button 2 “Settings”
After approximately 5 seconds
Display will change to”- - -”
- - -
con
Step 2
Continue holding for approximately
8 more seconds until display 
Changes to “Con” and “Left”
Channel indicator is displayed
Release Button 2