Nortel WLAN - Security Switch 2300 Series Quick Start Guide
Quick Start — Physical Installation
This section describes how to physically install a WSS. For more information about physical installation, see Nortel
WLAN—Security Switch 2300 Series Installation and Basic Configuration Guide.
WLAN—Security Switch 2300 Series Installation and Basic Configuration Guide.
Installing the Nortel WLAN Security Switch
Estimated timing: 10 minutes
A WSS can be installed on either a tabletop surface or in an equipment rack.
outlines which installation
methods are available for each WSS model.
When choosing a location for the WSS, ensure that:
•
The power outlet is within 1.82 m (6 ft) of the device.
•
There is proper heat dissipation from and adequate ventilation around the
switch.
switch.
Tabletop Installation
Step
Action
1
Ensure that the table surface supports at least 3 kg (6.6 lb).
2
Carefully turn the WSS upside down on a clean work surface with no debris.
3
Wipe the four placement locations for the rubber feet to clear away any oil or dust.
Each location area is marked with an ‘X’.
Each location area is marked with an ‘X’.
4
Attach the four rubber adhesive feet over the ‘X’s.
5
Turn the WSS right-side up, and place the switch in position on the table.
End
Equipment Rack Installation
Step
Action
1
Remove the four bracket screws from each side of the WSS.
2
Align a bracket over the screw holes:
•
For a front-mount equipment rack, align the bracket so that the bracket flange is
flush with the WSS front panel and away from the switch.
flush with the WSS front panel and away from the switch.
•
For a center-mount equipment rack, align the bracket so that the bracket flange
is located near the center screw holes, as shown in
is located near the center screw holes, as shown in
Table 2: Installation methods
WSS model
Tabletop
Front-mount rack
Center-mount rack
2350
X
2360/2361
X
X
2380
X
X
X
2382
X
X
X