Chapter 4    Setting Up RACs
Managing Remote Access Concentrators Using Annex Manager
Indonesia(E1/R2)
NewZealand(E1/R2)
The
Edit WAN Module
 window selects the
Default
 and
Other
 buttons based on
current
Switch Type
 settings:
 Default is selected if you do not set the switch type before
using the
Edit Wan Module
 window.
Other displays as selected if the switch type you set using the
CLI
 or
admin
 command is not one of the switches listed in the
Annex Manager Switch Type list. Annex Manager ignores
Other
 and does not change the current switch type.
Buildout allows adjustment of the cable loss measurement
between the last T1 signal regenerator and your location. This
measurement is supplied by the telephone company at
installation. Adjust your buildout based on this measurement.
The measurements are in decibels. There are four choices:
 0_dB
7.5_dB
15_dB
22.5_dB
FDL Type allows configuration of the FDL standard. It
describes the facilities data link use. This allows the telephone
company to read the statistics maintained by a RAC and to
perform diagnostic tests. There are two choices:
att for ATT-54016 ESF FDL
ansi for ANSI-T1-403 FDL
Table 4-1: Default Switch Types
Module Type
Default Switch Type
CAS T1
US/N. American (Chan T1)
CAS E1
CCITT 9E1/R2
PRI T1
5ESS9T1 ISDN)
PRI E1
ETS1 (E1 ISDN)