53000PR Series
NOTE: 
Pan capacity reflected is the actual amount of pans that are clearly accessible by the operator.  Units with multiple covers may actually have 
additional pan capacity that is partially obstructed by the cover divider/mullion. Remote rails intended to be connected to separate low-temp 
system, can be as small as (6) pans on any size base.
*BTU load and capacity ratings based on 100F ambient plus 30% for usage and product loading in base.  Final system selection should consider 
usage requirements and combined loads.  Recommended HP applied to self-contained (single) unit of equal storage capacity; increased HP may 
be appropriate in some remote applications.
Evaporator BTU/TD reflects NSF refrigerated base requirements when base is provided with +20F system separate from -10F rail system.
  
Length
 72"
75" 
78" 
81"
84"
90"
105"
117"                  
Model 33"
53372PR
53375PR
53378PR
53381PR
53384PR
53390PR
533105PR
533117PR
# of doors 
(9” mech.)
(3) 21"
(2) 21", (1) 
24"
(2) 24", (1) 
21"
(3) 24"
(2) 24", (1) 
27”
(3) 27"
(4) 24" 
 (4) 27"              
# Pans
(10-16) 1/6
(10-16) 1/6
(10-18) 1/6
(10-20) 1/6
(12-20) 1/6
(12-22) 1/6
(14-24) 1/6
(14-28) 1/6
Min. Length of Rail 41”
41”
41”
41”
48”
48”
55”
55”
Storage Cu. Ft. 
33”
15.91
16.78
17.65
18.52
19.39
21.12
25.46
27.78
Storage Cu. Ft. 
29”
13.37
14.10
14.83
15.56
16.28
17.74
21.39
23.33
Work surface 
Depth 33”
14.8” wide
14.8” wide
14.8” wide
14.8” wide
14.8” wide
14.8” wide
14.8” wide
14.8” wide
Recommended 
H.P./Refrigerant
1/2hp/404a
1/2hp/404a
1/2hp/404a
1/2hp/404a
1/2hp/404a
1/2hp/404a
3/4hp/404a
3/4hp/404a
Amps
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
Volt/Cycle/Phase  115/60/1
115/60/1
115/60/1
115/60/1
115/60/1
115/60/1
115/60/1
115/60/1         
Ship Wt. - lbs.
638
669
688
706
744
797
819
875
BTU Design load* 930/1080
1033/1109
1033/1138
1033/1167
1137/1226
1182/1275
1343/1517
1550/1633
Evap BTU/TD 
*Rail/Base
680/1262
756/1299
756/1335
832/1372
832/1409
907/1483
1058/1831
1210/1978
              53000PR SERIES REMOTE REFRIGERATORS WITH STANDARD DEPTH RAISED RAIL
Length
33"
36"
39"
42”
51"
54"
57"
60"
63" 
Model 33"
53333PR 53336PR
53339PR
53342PR
53351PR
53354PR
53357PR
53360PR
53363PR
# of doors 
(9” mech.)
(1) 24" 
(1) 21" + 6" 
coil hsg.
(1) 24" + 6" coil 
hsg.
(1) 27" + 6" coil 
hsg.
(2) 21" 
(1) 21", (1) 
24" 
(2) 24" 
(1) 24", (1) 
27”
(2) 27"
# Pans
(6-8) 1/6
(6-8) 1/6
(6-10) 1/6
(6-10) 1/6
(6-12) 1/6
(6-14) 1/6
(8-14) 1/6
(8-16) 1/6 (10-16) 1/6
Min. Length of Rail
27”
27”
27”
27”
27”
27”
34”
34”
41”
Storage Cu. Ft. 
33”
4.63
5.50
6.37
7.23
9.84
10.71
11.57
12.44
13.31
Storage Cu. Ft. 
29”
3.89
4.62
5.35
6.08
8.26
8.99
9.72
10.45
11.18
Work surface 
Depth 33”
14.8” 
wide
14.8” wide 14.8” wide
14.8” wide
14.8” wide
14.8” wide
14.8” wide 14.8” 
wide
14.8” wide
Recommended 
H.P./Refrigerant
1/3hp/
404a
1/3hp/404a 1/3hp/404a
1/3hp/404a
1/3hp/404a
1/3hp/404a
1/3hp/404a 1/3hp/
404a
1/2hp/404a
Amps
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
Volt/Cycle/Phase  115/60/1
115/60/1
115/60/1
115/60/1
115/60/1
115/60/1
115/60/1
115/60/1
115/60/1
Ship Wt. - lbs.
400
419
438
475
494
513
544
563
619
BTU Design load* 302/455
302/492
378/529
378/566
454/840
529/877
529/914
605/950
930/1051
Evap BTU/TD 
*Rail/Base
23/120
23/120
23/120
31/120
31/120
35/120
35/120
35/120
605/987