Руководство Пользователя для Intermec ck1

Скачать
Страница из 172
Chapter 4 — Communicating Through Modem and Null Modem Connections 
CK1 Handheld Computer User’s Manual 
61 
Configuring PPP Communications  
To communicate using a serial connection to the Ethernet 
network, you need to configure the following Point-to-Point 
protocol (PPP) communications parameters:  
•  Server 
•  Media 
•  Baud rate 
•  Timeout 
•  Host IP address 
•  Peer IP address 
To configure PPP communications 
1  From the System Setting screen, press X to highlight the PPP 
icon, and press Enter. The PPP screen appears. 
Server:
Media:
Baud:
Timeout:
Host IP:
Peer IP:
Setting
Enabled
Direct Link
115200
  6000
 172.16.10.1
172.16.10.2
UG
X
 
2  If the Server check box is not already selected, press T to 
select it.  
3  Press Space to enable or disable the server. If Server is 
enabled, the CK1 is a PPP server with a specific IP address.  
Enable Server if you plan to use a dial-in connection through 
the serial dock, which uses null modem communication. For 
help configuring a dial-in connection over null modem, see 
“Configuring the Windows Dial Settings for a Null Modem 
Connection” on page 79.