Справочное Руководство для Intermec 1555

Скачать
Страница из 178
Sabre 1555 RFID & Bar Code Reader Programmer’s Reference Manual
E-4
Table E-2  Sabre 1555 Environmental Specifications
Power Usage
The current use for the Sabre 1555 unit when operating in interactive mode are listed 
in Table E-3.
Specification
Value
Operating temperature
-20° to 50°C (-22° to 122°F) — standard
0° to 50°C (32° to 122°F)  — PDT
Note:  for 2450 MHz limited on continuous runtime 
at ambient temperatures >
25°C (77°F)
Storage temperature
(PDT and standard)
-40° to 70°C (-40° to 168°F) — PDT and standard
Battery storage temperature
-20° to 60°C (-4° to 140°F)
Humidity
0-95% noncondensing
Shock
Twenty-six 1.22 m (4-ft) drops to concrete
Vibration
Class 3 SAE off-road vehicle specification
Environmental
Scanner sealed against windblown rain and dust 
(IEC 529 rated at IP54)
ESD
Conforms to 6 KV rating per IEC 801-2
EMI Emissions
Conforms to Class A FCC Part 15, RSS 210 and 
CISPR 22 Class B
Approvals
UL & cUL listed, C22.2 No. 950/UL 1950, TÜV 
Hheinland GS Licensed EN 60950, EN 60825-1, 
CD marked, C-Tick marked
Table E-3  Sabre 1555 Current Use with RF Power On
Version
Parameters
Current Use (mA)
915 MHz
Interactive mode command (IMC) 
deactivated (1555 in sleep mode, no LCD)
<1
IMC activated
150
Bar code decode ON
200
IMC activated, RF submodule ON, no RF 
commands
350
IMC activated, RF submodule ON, RF 
commands
950