Troubleshooting
188  
SP/XX/RM/10/E/960401
Operating problems—all models
symptoms
possible causes
action (
Ð
refer to)
no beeps or green indicator
LED during reading,
no transmission
• 
installation problem
check ScanPlus power supply,
connections (
Connection diagram for
your interface), product components
• 
configuration problem
• 
check you have the correct
product components (ScanPlus
model, cables, CMM, external
power supply as applicable)
• 
check you have the correct
number of flashes for your
interface at power-up (
Interfaces)
• 
reselect correct interface number
for your system if necessary
(
Predefined interface numbers
section for your interface,
Compose interface number)
• 
if you have just configured the
ScanPlus, make sure you have
finished correctly—the ScanPlus
may be waiting for an End
Selection for example
• 
symbology not selected
activate the required symbology
(
Symbologies—Activation)
• 
symbology not supported by your
ScanPlus model
see the user’s leaflet (if available) for
your ScanPlus model, read the
appropriate test code (
Test codes)
• 
good read beep / LED deactivated activate if required (Beeps / green
indicator LED)
• 
barcode length incompatible with
ScanPlus configuration
(minimum/fixed length parameter
settings)
• 
check bar code
• 
change barcode length setting for
your symbology (
Symbologies)
• 
ScanPlus configured for check
digit and no check digit present in
code
• 
check bar code
• 
change check digit configuration
for your symbology if applicable
(
Symbologies)
• 
you have read a pushbutton
activation code with a non-
pushbutton ScanPlus model
perform the global reset procedure
provided at the beginning of this
section (
Troubleshooting - Before you
contact your UBI representative . . .)