Справочное Руководство для Intermec 1800

Скачать
Страница из 212
RS-232
SP/XX/RM/10/E/960401
   121
Dual-output CMM—Jumper settings
To change the jumper settings, remove the four attachment screws and remove the cover of
the CMM.
Jumper settings are identical for standard and reverse gender dual-output RS-232 CMMs.
Make sure the 
TO
 
HOST
 and 
TO
 
TERMINAL
 labels are correctly positioned when you
reassemble the CMM.
power supply
input
ScanPlus
input
DB 25-position
male connector
terminal 
Ï
 DCE
DB 25-position
female connector
DTE 
Ð
 host
1
+
+
2%6 !
UBI
DUAL  RS232
C4
C13
C11
C7
C6
C8
C2
R3
R1
R2
R4
C3
X5
3
3
3
1
1
1
+
+
+
+
+
C1
 
IC2
 
IC3
 
IC4
 
IC1
 J3
 J4
X1
X2
X3
C12
+
+
 
J1
 
J2
< 2
RXD
> 3
TXD
< 4
CTS
> 5
RTS
7
GND
9
+5V
TXD
< 2
RXD
> 3
RTS
< 4
CTS
> 5
GND
7
+5V
9
C16
C5
C10
Data transmission
transmit to host and terminal
transmit to terminal only
1
X5
transmit to host only (default)
3
3
3
1
1
1
X1
X2
X3
1
X5
1
X5
3
3
3
1
1
1
X1
X2
X3
3
3
3
1
1
1
X1
X2
X3
ScanPlus-host RTS/CTS handshaking
RTS/CTS handshaking on (default)
1
X5
3
3
3
1
1
1
X1
X2
X3
RTS/CTS handshaking off
1
X5
3
3
3
1
1
1
X1
X2
X3