Инструкции По Установке для Intermec 1800
4. Data transmission settings laser emulation
ScanPlus 1800 - Installation Manual
63
laser emulation
- default values (*) are for standard laser with trigger
- transmitted symbology type :
- PDF417, Telepen : data is transmitted in Code 128 format
- all other symbologies : data can be transmitted in original barcode format or in Code 39
format
transmitted symbology type
- transmits data in original barcode format or in Code 39 format
transmission in original code format (*)
\5E\00\60
transmission in Code 39
\5E\01\60
- original code must not contain characters not
supported by Code 39
margin size
- defined in increments of narrow bar width (50 µs)
10 x narrow bar width (*)
\5A\0A\60