Руководство По Установке для Citel 1100
EXTender 1100A Remote Module: Quick Installation Guide
20
Testing the Installation
If the units are installed properly, but you still cannot connect the remote
telephone to the Switch Module, you should test the Dial Numbers.
telephone to the Switch Module, you should test the Dial Numbers.
1. Connect the Remote Module’s telephone line to an analog phone
2. Connect the Switch Module’s telephone line to an analog phone also
3. Call the Switch Module’s telephone number from the Remote Module’s
location. Confirm that the phone rings and that the voice path is established.
4. Make the necessary changes to the Dialback numbers if required. Reconnect
the analog lines to the Switch and Remote Modules and attempt to connect.
If problems persist refer to the Trouble Shooting section in the System
Administrator’s Guide. There are optional configuration parameters also available
to the administrator.
Administrator’s Guide. There are optional configuration parameters also available
to the administrator.
Optional Configuration Method
There is an optional configuration method also available to the administrator.
Enabling the Management Browser
The Remote Module can also be configured via an HTML interface. The Web
Server feature must first be enabled in order to administer the units with this
method.
Server feature must first be enabled in order to administer the units with this
method.
1. Web Server – In order to configure the units using the Management Browser
(MB) the Web Server must be set to “Enabled.”
Path: Remote->Configuration->IP->LAN
2. There must also be a valid IP Address entered for the Remote.
Path: Remote->Configuration->IP->LAN->Address
Additional Management Browser parameters can also be configured either prior
to launching the MB or any time after.
to launching the MB or any time after.
3. Web Timeout – This parameter determines the amount of time a
Management Browser screen can be left idle (no programming activity)
before the session is terminated.
before the session is terminated.
Path: Remote->Configuration->IP
4. Web Refresh LED – The Port Status LEDs update every 10 seconds. If the
frequent updates are found to be a hindrance during administration of the
Switch Module the LED refreshing can be disabled.
Switch Module the LED refreshing can be disabled.
Path: Remote->Configuration->IP