Справочник Пользователя для SATO CT400
CT4xx Series Quick Guide
Pg 2
CT4xx Series Quick Guide
Pg 11
6. If you are still unable to get printer output, try the Hex Dump as described in
Step 5 under the Parallel Interface troubleshooting. In this case, the printer
monitors its RS232C interface for incoming data.
monitors its RS232C interface for incoming data.
What You Get
The CT Series Thermal Transfer printer comes packed in a protective carton.
Included in the carton are the following items :
Included in the carton are the following items :
7. From the Hex Dump, if you are seeing no extra 0D 0A (CR & LF)
characters, and are using BASIC, refer to the beginning of the Command
Code section. It provides hints for writing a SATO program in BASIC.
Code section. It provides hints for writing a SATO program in BASIC.
• CT400 / CT410 Printer
• Quick Guide
Error Signals
• Driver / Manual CD ROM
The 7-segment LED, Front Panel LED Indicators and Buzzer provide a
visual/audio indication of the type of error encountered.
visual/audio indication of the type of error encountered.
• Power Module AC Power Cord
• Cleaning Solution & Cloth (Not for Export out of Singapore)
• Cleaning Solution & Cloth (Not for Export out of Singapore)
LED Indicators
Error
Corrective
Dis-
play
play
LINE ERROR
Buzzer
Condition
Action
0
ON
1
Beep
Flash Memory
error
Replace Flash ROM
1
Not
Assigned
2
ON
1 Beep
Motherboard error Replace PCB
3
ON
1Beep
EEPROM error
Replace EEPROM
4
ON
1 Beep
Electrical Head
Replace Print Head
5
Blink
3 Beeps
Head not latched
Latch Print Head
6
Blink
3 Beeps
Out of Paper
1) Replenish paper
2) Route Paper thru sensor
2) Route Paper thru sensor
7
Blink
3 Beeps
Sensor error
1) Select correct sensor
2) Adjust sensor level
2) Adjust sensor level
8
Blink
3 Beeps
Cutter error
Connect cutter
8.
ON
ON
Program
download error
Retry download
9
Blink
3
Beeps
Ribbon End (TT
mode only)
Replace ribbon
A
ON
1
Beep
Receive buffer
overflow
1) Modify host SW
2) Select correct protocol
2) Select correct protocol
b
ON
1
Beep
Parity error
(Serial I/F only)
Correct Parity Settings
c
ON
1
Beep
Framing error
(Serial I/F only)
Correct data bit setting
d
ON
1
Beep
Overrun error
(Serial I/F only)
Correct flow control
settings
settings
E
ON
1
Beep
LAN Time Out
Error
Replace LAN I/F
F 3
Beeps
Download Font /
Graphic Error
Correct data stream