7.1.4.1  Notification Packet Description 
Application Header: 
  
Command DC_PARAM_CHG_MSG  0x04 
Data Count  2 
0x02 
Application Data: 
  
Data[0] ParamId 
nn 
Data[1] Value 
nn 
 
7.1.4.2 Data Description 
 ParamId: 
 
 
Data Type: 
Unsigned 8 bit integer 
  Max: 
 255. 
 
 
Value:  
 
The Current Value for this system parameter. 
 
 
Data Type: 
Unsigned 8 bit integer 
Max: 
Set by the Max Value per the Parameter Definition response Packet for 
the Parameter Id of this packet. 
7.1.4.3 HOST Response 
The MC-12 does not expect any response from the HOST. 
7.1.4.4  Supported System Parameters 
The following parameters will be supported by this Parameter Change Notification: 
 
Parameter MC-12 
Parameter 
Name 
MC-1 
ParamId(V4.00) 
Current Effect 
PROGRAM 
Mute MUTE 
System Volume 
VOLUME 
Balance LR_BALANCE 
Input Selection 
INPUT 
Record/Zone 2 On/Off 
RECORD_ENABLED 
18 
Zone 2 Volume 
Z2_VOL 
154 
Zone 2 Balance 
Z2_BAL 
156 
Zone 2 Mute 
Z2_MUTE 
157 
Bass BASS  167 
Treble TREBLE  168 
Loudness LOUDNESS 169 
Tilt TILT  174 
Menu Background On/Off 
MENU_BKGND 
190 
 
Note:  The Record/Zone 2 On/Off only applies to the MC-12 Record zone.  The Zone 2 Volume, Zone 2 
Balance and Zone 2 Mute only apply to the MC-12 Zone-2. 
 
For Input Parameter Change Notifications the Input Value is a MC-12 to MC-1 input mapping, as shown in 
 