Cabinet
Cabinet Side Seal
Top Retainer Bar
Window sill
1” long screw
Outer edge of window sill 
Leveling bolt
Leveling bracket
#8 screws
Cabinet track
5
Installing Cabinet in Window 
(Flush Mount)
1. Attach cabinet side seals to the existing holes in the cabinet
using the six (6) screws supplied (Fig. 6). 
2. Open window and mark the center of window sill. Carefully
place cabinet in window and align center mark on the bottom
tie bar with the center mark on the window sill (Fig. 7).
3. Close window until it touches behind top retainer bar. Do not
close window so tightly that sliders cannot move. (Do not
release your grip on the cabinet until the lower window sash is
in its final position) (Fig. 7).
4. Attach the cabinet to the window sill by driving two (2) 1” long
screws through each cabinet track into the window sill (Fig. 8).
5. Brackets may be attached to cabinet in either direction for
maximum support, depending on the depth of the window sill.
Place the leveling bracket with leveling bolt under cabinet and
attach to the cabinet with two (2) #8 screws. Tighten screws
through cabinet into the smaller holes in the bracket. Placement
of bracket and screws to slots on cabinet track will depend on
size of the window sill. Position the brackets so bolts will rest
securely on window sill (Fig. 8 & 10).
Be sure cabinet maintains an outward pitch. Air conditioner should
slant slightly downward on the outside as shown by 1/2 a bubble
off on a carpenter’s level. This outward pitch prevents water from
entering the room.
Installation Other Than Flush Mount
In order to install the unit with more of it projecting into the room, it
will be necessary to relocate the top retaining bar, side seals and bottom
tie bar.
1. Check to make sure the cabinet’s outside side louvers will not be
blocked when the unit is moved farther into the room.
2. Remove the top retainer bar, cabinet side seals and bottom tie bar
from the cabinet. Relocate them for the desired projection into the
room.
3. Using the top retaining bar and cabinet side seals as templates,
locate and drill five (5) 7/32” mounting holes on the top of the
cabinet and three (3) on each cabinet side.
4. Use sealing material to fill the holes in the cabinet top and sides that
become exposed when the top retaining bar and cabinet side seals
were relocated.
5. Follow all preceding instructions.
Consult your authorized dealer or importer for alternative installation
instructions. 
Caution: Do not drill a hole in bottom pan. Unit is designed to
operate with approximately 1/2” of water in bottom pan.